Literature DB >> 8396105

Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing.

W J Stok1, F Baisch, A Hillebrecht, H Schulz, M Meyer, J M Karemaker.   

Abstract

Noninvasive cardiac output (CO) measured by arterial pulse analysis was compared with that measured by inert gas rebreathing in six healthy male volunteers. Pulse contour analysis was applied to the pressure wave output of a Finapres, which noninvasively measures continuous arterial pressure in a finger. Data were collected before, during, and after a 10-day 6 degrees head-down tilt experiment. Intravenous saline loading and lower body negative pressure stimuli varied CO over 2.8-9.6 l/min, as measured by the rebreathing technique. Because pulse contour provides only relative changes in CO, to obtain absolute values it must be calibrated against another measurement. Pulse contour data were calibrated every measurement day against the mean of two to four control rebreathing CO measurements before the lower body negative pressure or intravenous saline loading stimuli. Using one averaged calibration factor per subject for a total of 27 days, we compared the results of both methods. The linear regression between pulse contour (Pc CO) and rebreathing CO (Rebr CO) was Pc CO = 0.15 + 0.98(Rebr CO) (r = 0.96). The standard deviation of the difference of the two methods was 0.5 l/min (n = 205), excluding data used for calibration. By monitoring pulse contour CO before and during rebreathing, the rebreathing maneuver itself was shown to produce a substantial increase in CO that was mainly related to an increase in heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8396105     DOI: 10.1152/jappl.1993.74.6.2687

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  25 in total

1.  Sympathetic nervous system activity and cardiovascular homeostatis during head-up tilt in patients with spinal cord injuries.

Authors:  S Houtman; B Oeseburg; R L Hughson; M T Hopman
Journal:  Clin Auton Res       Date:  2000-08       Impact factor: 4.435

2.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

3.  Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods.

Authors:  Jani Penttilä; Amir Snapir; Erkki Kentala; Juha Koskenvuo; Jussi Posti; Mika Scheinin; Harry Scheinin; Tom Kuusela
Journal:  Eur J Clin Pharmacol       Date:  2006-03-29       Impact factor: 2.953

4.  Is the magnitude of acute post-exercise hypotension mediated by exercise intensity or total work done?

Authors:  Helen Jones; Keith George; Ben Edwards; Greg Atkinson
Journal:  Eur J Appl Physiol       Date:  2007-09-19       Impact factor: 3.078

5.  The acute post-exercise response of blood pressure varies with time of day.

Authors:  Helen Jones; Christopher Pritchard; Keith George; Ben Edwards; Greg Atkinson
Journal:  Eur J Appl Physiol       Date:  2008-06-20       Impact factor: 3.078

6.  Lack of changes in carotid artery compliance with systemic nitric oxide synthase inhibition.

Authors:  J Sugawara; Y Saito; S Maeda; M Yoshizawa; H Komine; M Nakamura; R Ajisaka; H Tanaka
Journal:  J Hum Hypertens       Date:  2014-01-09       Impact factor: 3.012

7.  Baroreflex-mediated changes in cardiac output and vascular conductance in response to alterations in carotid sinus pressure during exercise in humans.

Authors:  Shigehiko Ogoh; Paul J Fadel; Peter Nissen; Øeivind Jans; Christian Selmer; Niels H Secher; Peter B Raven
Journal:  J Physiol       Date:  2003-05-02       Impact factor: 5.182

8.  Effects of leg blood flow restriction during walking on cardiovascular function.

Authors:  Christopher P Renzi; Hirofumi Tanaka; Jun Sugawara
Journal:  Med Sci Sports Exerc       Date:  2010-04       Impact factor: 5.411

9.  Circulatory response evoked by a 3 s bout of dynamic leg exercise in humans.

Authors:  W Wieling; M P Harms; A D ten Harkel; J J van Lieshout; R L Sprangers
Journal:  J Physiol       Date:  1996-07-15       Impact factor: 5.182

10.  Differences in circulatory control in normal subjects who faint and who do not faint during orthostatic stress.

Authors:  A D ten Harkel; J J van Lieshout; J M Karemaker; W Wieling
Journal:  Clin Auton Res       Date:  1993-04       Impact factor: 4.435

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.