Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy.

S Vatnitsky1, H Järvinen.   

Abstract

The suitability of a natural diamond detector with a special contact system for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the diamond detector was analysed by comparison with measurements using an ionization chamber and a silicon diode detector. The good stability, high response and good spatial resolution of the diamond detector were demonstrated by relative measurements in high-energy photon and electron beams and around the 137Cs source of an afterloading device. The application of the diamond detectors for relative as well as absolute dose measurements of beta ray ophthalmic applicators was also highlighted. It is concluded that the diamond with the special contact system is a suitable detector for relative dose measurements in a wide variety of applications, especially when high response and high spatial resolution are required.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8381236     DOI: 10.1088/0031-9155/38/1/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors.

Authors:  David Klein; Tina Marie Briere; Rajat Kudchadker; Louis Archambault; Luc Beaulieu; Andrew Lee; Sam Beddar
Journal:  Radiat Meas       Date:  2012-08-24       Impact factor: 1.898

3.  Percent depth-dose distribution discrepancies from very small volume ion chambers.

Authors:  Vikren Sarkar; Brian Wang; Hui Zhao; Bart Lynch; Joshua A James; Kiernan T McCullough; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Characterization of a new commercial single crystal diamond detector for photon- and proton-beam dosimetry.

Authors:  Yuichi Akino; Archana Gautam; Len Coutinho; Jan Würfel; Indra J Das
Journal:  J Radiat Res       Date:  2015-08-12       Impact factor: 2.724

5.  Measured transverse-axis dosimetric parameters of the model STM1251 125I interstitial source.

Authors:  Z Li; J F Williamson
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector.

Authors:  Wolfram U Laub; Richard Crilly
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102