Literature DB >> 8372857

Single umbilical artery: accurate diagnosis?

T B Jones1, Y Sorokin, R Bhatia, I E Zador, S F Bottoms.   

Abstract

OBJECTIVE: We sought to evaluate the accuracy of ultrasonographic, obstetric, and neonatal diagnosis of a single umbilical artery. STUDY
DESIGN: We studied 17,777 consecutive singleton births from women who had undergone ultrasonographic examination at our hospital. A single umbilical artery was confirmed in 37 cases (0.2%) by two clinical methods or by pathologic assessment. Outcome of neonates with a single umbilical artery was compared with the outcome of neonates with either two or three vessel cords.
RESULTS: Ultrasonographic diagnosis had a 65% sensitivity and positive predictive value. Obstetricians and pediatricians failed to diagnose 24% and 16% of the cases, respectively. On average, neonates with a single umbilical artery weighed 320 gm less, were delivered 1 week earlier, and had lower Apgar scores than neonates with three vessel cords (p < 0.01 in each case.)
CONCLUSION: Although early gestational age may account for some cases not diagnosed by ultrasonography, there is a little justification for missing the diagnosis after delivery. Greater emphasis on clinical examination of the umbilical cord is needed to identify neonates at risk of associated malformations.

Entities:  

Mesh:

Year:  1993        PMID: 8372857     DOI: 10.1016/0002-9378(93)90615-p

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  4 in total

1.  Determination of risk factors and perinatal outcomes of singleton pregnancies complicated by isolated single umbilical artery in Turkish population.

Authors:  Fırat Tülek; Alper Kahraman; Salih Taşkın; Esra Özkavukçu; Feride Söylemez
Journal:  J Turk Ger Gynecol Assoc       Date:  2015-03-01

2.  Single umbilical artery: Does side matter?

Authors:  Mark Santillan; Donna Santillan; Diedre Fleener; Barbara Stegmann; Gideon Zamba; Stephen Hunter; Jerome Yankowitz
Journal:  Fetal Diagn Ther       Date:  2012-06-01       Impact factor: 2.587

3.  The Risk Factors and Neonatal outcomes of Isolated Single Umbilical Artery in Singleton Pregnancy: A Meta-analysis.

Authors:  Xiaohua Luo; Shanshan Zhai; Na Shi; Mei Li; Shihong Cui; Yajuan Xu; Limin Ran; Lidan Ren; Teng Hong; Rui Liu
Journal:  Sci Rep       Date:  2017-08-07       Impact factor: 4.379

Review 4.  Urologic anomalies and two-vessel umbilical cords: what are the implications?

Authors:  Christopher W Johnson; Steven Y Tennenbaum
Journal:  Curr Urol Rep       Date:  2003-04       Impact factor: 2.862

  4 in total