Literature DB >> 8365390

The vibration characteristics of chain saws and their influence on vibration white finger disease.

S G Hutton1, N Paris, R Brubaker.   

Abstract

The vibration from chain saws can cause vibration-induced white finger disease (VWFD). Measurements of vibration levels on the front and rear handles of different chain saw-types, and on the operator's middle finger were collected at three logging camps on Vancouver Island. Factors effecting the vibration levels on the finger and handles were investigated. The acceleration at the firing frequency was found to be the dominant factor effecting handle and finger vibration. Other factors which were investigated were: grip force; the presence of handle covers; and chain sharpening procedure. Weighted acceleration levels are calculated and this information is used to assess the latency period for fallers to develop VWF disease.

Entities:  

Mesh:

Year:  1993        PMID: 8365390     DOI: 10.1080/00140139308967956

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  1 in total

1.  Evaluation of hand-arm vibration (HAV) exposure levels among grounds maintenance workers: An observational human exposure measurement study.

Authors:  Jonghwa Oh
Journal:  Health Sci Rep       Date:  2022-07-20
  1 in total