| Literature DB >> 35873393 |
Abstract
Entities:
Keywords: backpack blower; daily vibration exposure; grass trimmer; hand‐arm vibration (HAV)
Year: 2022 PMID: 35873393 PMCID: PMC9301294 DOI: 10.1002/hsr2.731
Source DB: PubMed Journal: Health Sci Rep ISSN: 2398-8835
Vibration total values (a hv) and daily vibration exposure A(8) values
| Vibration total value, | Daily vibration exposure, | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Participant | Hand side | Day 1 | Day 2 | Day 3 | Day4 | Day 5 | Day 6 | Day 1 | Day 2 | Day 3 | Day4 | Day 5 | Day 6 |
| 1 | Right | 3.6 | 3.5 | 3.9 | 4.1 | 3.5 | – | 3.0 | 3.0 | 2.5 | 3.6 | 2.5 | – |
| Left | 3.8 | 3.5 | 3.7 | 4.4 | – | – | 3.2 | 3.1 | 2.4 | 3.8 | – | – | |
| 2 | Right | 4.2 | – | 7.2 | 5.5 | 3.2 | 4.3 | 3.6 | – | 4.6 | 4.7 | 2.2 | 3.4 |
| Left | 4.3 | – | 8.4 | – | 3.2 | 4.8 | 3.6 | – | 5.4 | – | 2.3 | 3.8 | |
No sampling.
Data unavailable due to the breakage of the adapter strip during sampling.
Figure 11/3 octave band frequency analysis for right‐hand grass trimmer operation (A, C, and E) and backpack blower operation (B, D, and F) of participant 1 on sampling Days 1, 4, and 5