Literature DB >> 8365122

Nickel sensitivity and the implantation of orthopaedic prostheses.

D J Gawkrodger1.   

Abstract

There is no evidence that nickel-sensitive patients, when given a modern plastic-to-stainless-steel hip replacement, develop cutaneous reactions or loosening of their prostheses. However, eczema is occasionally seen with static metal prostheses and eruptions sometimes accompanied the use of the older types of joint prosthesis. Modern plastic-to-metal joint replacements rarely cause sensitization to the composite metals. In the rare instances when this has been detected by patch testing, the affected patients have not developed eczema or loosening of their prostheses.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8365122     DOI: 10.1111/j.1600-0536.1993.tb03427.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  16 in total

1.  Factors to consider in joint prosthesis systems.

Authors:  Larry M Wolford
Journal:  Proc (Bayl Univ Med Cent)       Date:  2006-07

2.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 3.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

4.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

5.  A subdermal source: contact dermatitis.

Authors:  Alexander L Fogel; Michelle Longmire; Kerri E Rieger; Kavita Y Sarin
Journal:  Am J Med       Date:  2015-03-05       Impact factor: 4.965

6.  Cytotoxicity study of plasma-sprayed hydroxyapatite coating on high nitrogen austenitic stainless steels.

Authors:  C P O Ossa; S O Rogero; A P Tschiptschin
Journal:  J Mater Sci Mater Med       Date:  2006-11-22       Impact factor: 3.896

Review 7.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

8.  Orthopaedic surgery in a patient with metal sensitivity.

Authors:  Raviraj Adala; Murali Chakravarthy; Vijayakumar Srinivas; Sanjay Pai
Journal:  J Cutan Aesthet Surg       Date:  2011-01

9.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

10.  Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty.

Authors:  Nadim James Hallab; Marco Caicedo; Alison Finnegan; Joshua J Jacobs
Journal:  J Orthop Surg Res       Date:  2008-02-13       Impact factor: 2.359

View more