Electromagnetic interference in implantable pacemakers.

W Irnich, J M de Bakker, H J Bisping.   

Abstract

The inhibited pacemaker (VVI or AAI) has become the most popular in recent years because of its ability to combine a physiological advantage with economical current consumption in cases with spontaneous activity. One of its disadvantages is its sensitivity to external electromagnetic interference. Though today's pacemakers possess effective protection against most interference signals there may be instances in which patients are subjected to uncomfortable or even life-threatening situations. This is the case of "amplitude modulated" or "pulsed" fields with modulation frequencies in the physiological range. Fields of that sort have been found in the vicinity of a welder, an electric steel plant, and in medical practice where therapeutic currents were applied. Even touch-actuated switches may influence a demand pacemaker. However, these situations may be overcome by a device within the pacemaker for simple time analysis which can be carried out with few components. If electromagnetic fields of diathermy equipment are applied, today's pacemakers may react with intolerably high or low rates. They should, therefore, be avoided.

Entities:  

Mesh:

Year:  1978        PMID: 83621     DOI: 10.1111/j.1540-8159.1978.tb03441.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  [Does thermotherapy of prostatic hypertrophy interfere with pacemaker function? - First results of a pilot-study].

Authors:  G Jakl; M Nürnberg; K Steinbach; G Theyer; O Zechner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

Review 2.  Management of cardiac implantable electronic devices during interventional pulmonology procedures.

Authors:  Abhishek Kumar; Samjot Singh Dhillon; Spandan Patel; Matthias Grube; Amit Noheria
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

3.  Echocardiography induced tachycardia in a patient with a minute ventilation rate responsive pacemaker.

Authors:  Chotikorn Khunnawat; Siddharth Mukerji; Sundar Sankaran; Ranjan K Thakur
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

4.  Influence of electromagnetic interference on implanted cardiac arrhythmia devices in and around a magnetically levitated linear motor car.

Authors:  Motoyuki Fukuta; Noboru Mizutani; Katsuhisa Waseda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

5.  Reciprocal interaction between IK1 and If in biological pacemakers: A simulation study.

Authors:  Yacong Li; Kuanquan Wang; Qince Li; Jules C Hancox; Henggui Zhang
Journal:  PLoS Comput Biol       Date:  2021-03-10       Impact factor: 4.475

  5 in total