Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.

J A Davidson1.   

Abstract

The micromechanics of ultra high molecular weight polyethylene (UHMWPE) wear in total hip replacement are very complex. Polyethylene wear from the metal head and debris formation are two common types of wear. There are additional wear-related processes occurring at the metal-bearing surfaces that are not well-known, however. This study outlines these processes, including (1) surface wettability changes, (2) oxidative wear of metal surfaces, (3) microabrasion of metal surfaces from oxide film damage, and (4) surface abrasion from three-body polymethylmethacrylate and bone debris. These processes can contribute to metal ion release and a gradual increase in the roughness of the metal surfaces. This can lead to increased long-term UHMWPE wear. Of the metal alloys currently used in total hip replacements, Co-Cr-Mo alloy is significantly more resistant to roughening processes. Hard, stable, oxide: ceramic surfaces articulating against UHMWPE are essentially immune to these surface-roughening processes, however. In addition, they provide a more wettable surface, further minimizing polyethylene wear relative to metal surfaces. By analyzing metal release rates from metal-polyethylene wear tests, it is shown here that Co-Cr-Mo is gradually removed at a rate of about 0.1 micron per year (10(6) cycles), whereas 316L stainless steel is removed on the order of 0.2 microns per year and Ti-6Al-4V on the order of 1 micron per year. The wear rate of Co-Cr-Mo articulating against itself is reported to be still greater, at about 2-4 microns per year after an initial wear-in period. Because metal is gradually removed with articulation time, surface-hardening methods such as nitrogen ion implantation can be expected to provide only temporary resistance to these metal removal and surface-roughening processes. Hard, stable ceramic surfaces such as Al2O3 and ZrO2, however, can be expected to maintain their initial surface finish and thus minimize UHMWPE wear in the long term.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8358943

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  14 in total

Review 1.  Biological response to prosthetic debris.

Authors:  Diana Bitar; Javad Parvizi
Journal:  World J Orthop       Date:  2015-03-18

2.  Exposure of articular chondrocytes to wear particles induces phagocytosis, differential inflammatory gene expression, and reduced proliferation.

Authors:  Michael D Kurdziel; Meagan Salisbury; Lige Kaplan; Tristan Maerz; Kevin C Baker
Journal:  J Mater Sci Mater Med       Date:  2017-05-22       Impact factor: 3.896

3.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

4.  A surface modified ODS superalloy by thermal oxidation for potential implant applications.

Authors:  M C García-Alonso; J L González-Carrasco; P Pérez; V A Haanappel; M L Escudero; J Chao; M F Stroosnijder
Journal:  J Mater Sci Mater Med       Date:  2001-07       Impact factor: 3.896

5.  In vivo evaluation of bone tissue behavior on ion implanted surfaces.

Authors:  M Bosetti; A Massè; E Tobin; M Cannas
Journal:  J Mater Sci Mater Med       Date:  2001-05       Impact factor: 3.896

6.  Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Alberto Carli; Chelsea N Koch; Christina I Esposito; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

7.  Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene.

Authors:  Stephen M Petis; Edward M Vasarhelyi; Brent A Lanting; James L Howard; Douglas D R Naudie; Lyndsay E Somerville; Richard W McCalden
Journal:  Can J Surg       Date:  2016-02       Impact factor: 2.089

8.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

9.  Retrieval analysis of motion preserving spinal devices and periprosthetic tissues.

Authors:  Steven M Kurtz; Marla Steinbeck; Allyson Ianuzzi; André van Ooij; Ilona M Punt; Jorge Isaza; E R S Ross
Journal:  SAS J       Date:  2009-12-01

10.  Bearing-Foreign Material Deposition on Retrieved Co-Cr Femoral Heads: Composition and Morphology.

Authors:  Nishant M Tikekar; Anneliese D Heiner; Thomas E Baer; Karen M Kruger; John J Callaghan; Thomas D Brown; John J Lannutti
Journal:  Biomed Res Int       Date:  2015-07-05       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.