Literature DB >> 8352692

Strabismus following implantation of Baerveldt drainage devices.

M Muñoz1, R K Parrish.   

Abstract

OBJECTIVE: To describe the clinical features of strabismus following implantation of a Baerveldt glaucoma seton.
DESIGN: Case series of four patients with a minimum follow-up of 6 months.
SETTING: Specialized glaucoma referral center at Bascom Palmer Eye Institute/Ann Bates Leach Eye Hospital, Miami, Fla. PATIENTS: Consecutive sample of four patients with persistent binocular diplopia following implantation of a 350-mm2 Baerveldt glaucoma seton in the superotemporal quadrant.
RESULTS: Each patient presented with a characteristic pattern of either exotropia or hypertropia, or both. The deviation increased with gaze opposite the ipsilateral superior and lateral muscles and decreased in the field of action of the involved muscles. All patients demonstrated a convergence insufficiency type of exotropia.
CONCLUSION: These patients presented with a similar type of restrictive strabismus. Proposed mechanisms include an increase in the length-tension curve of the muscle induced by the underlying bleb and a posterior fixation effect as a result of scarring behind the implant.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8352692     DOI: 10.1001/archopht.1993.01090080092023

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  6 in total

1.  Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome.

Authors:  S Roy; E Ravinet; A Mermoud
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Binocular disturbance after glaucoma drainage device implantation.

Authors:  Ta Chen Chang; Kara M Cavuoto
Journal:  World J Ophthalmol       Date:  2014-08-12

3.  Motility disturbances in the tube versus trabeculectomy study during the first year of follow-up.

Authors:  Frederick M Rauscher; Steven J Gedde; Joyce C Schiffman; William J Feuer; Keith Barton; Richard K Lee
Journal:  Am J Ophthalmol       Date:  2008-11-26       Impact factor: 5.258

4.  Plate size reduction surgery for the Baerveldt 350-mm2 glaucoma implant for postoperative motor disturbance: A case report.

Authors:  Hirotaka Tanabe; Shunsuke Nakakura; Asuka Noguchi; Hitoshi Tabuchi; Yoshiaki Kiuchi
Journal:  Medicine (Baltimore)       Date:  2019-09       Impact factor: 1.817

5.  Assessment of Filtration Bleb and Endplate Positioning Using Magnetic Resonance Imaging in Eyes Implanted with Long-Tube Glaucoma Drainage Devices.

Authors:  Ichiya Sano; Masaki Tanito; Koji Uchida; Takashi Katsube; Hajime Kitagaki; Akihiro Ohira
Journal:  PLoS One       Date:  2015-12-07       Impact factor: 3.240

6.  Motility Changes and Diplopia After Baerveldt Glaucoma Drainage Device Implantation or After Trabeculectomy.

Authors:  Esma Islamaj; Caroline P Jordaan-Kuip; Koen A Vermeer; Hans G Lemij; Peter W T de Waard
Journal:  Transl Vis Sci Technol       Date:  2018-09-13       Impact factor: 3.283

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.