Color flow Doppler: imaging the upper extremity.

S Trager1, M Pignataro, J Anderson, J M Kleinert.   

Abstract

Dynamic values of key vessel diameter, blood velocity, and flow rate in the upper extremity were obtained in 20 healthy volunteers by means of color flow Doppler imaging with a 7.5 MHz transducer. Recordings were made of the brachial, radial, posterior radial recurrent, ulnar, and digital arteries. Radial and ulnar vessels were evaluated at both wrist and midcarpal levels. Diameter and velocity changes were followed throughout the cardiac cycle, and a true mean flow was computed. Mean diameters of the digital vessels ranged from 0.9 mm in the small finger to 1.3 mm in the thumb. Brachial flows ranged from 4.6 to 89.9 ml/min, radial flows from 0.9 to 15.3 ml/min, and ulnar flows from 0.6 to 79.9 ml/min. At the midcarpal level, flows ranged from 0.2 to 68.4 ml/min for the ulnar artery and from 0.8 to 42.9 ml/min for the radial artery. Variability between individuals was also demonstrated in artery dominance: eleven ulnar dominant, seven radial dominant, and two equal (within 25% of each other). The accuracy and ease of use of this technique in measurement of vessels are limited when vessels are less than 1.5 mm in diameter although the technique provides quantitative values to 0.5 mm.

Mesh:

Year:  1993        PMID: 8349968     DOI: 10.1016/0363-5023(93)90304-L

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  3 in total

1.  Evaluation of microfluidic blood gas sensors that combine microdialysis and optical monitoring.

Authors:  C G Cooney; B C Towe
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

2.  Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience.

Authors:  Ruth P Lim; Pippa Storey; Iliyana P Atanasova; Jian Xu; Elizabeth M Hecht; James S Babb; David R Stoffel; Hugo Chang; Kellyanne McGorty; Qun Chen; Henry Rusinek; H Michael Belmont; Vivian S Lee
Journal:  Radiology       Date:  2009-06-30       Impact factor: 11.105

3.  Extra-anatomic temporary intravascular shunting to assist with replantation of an amputated hand with prolonged ischemic time.

Authors:  David de Launay; Sarah Shiga; Matthew Laschuk; Timothy Brandys; Derek J Roberts
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-08-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.