Trabecular bone modulus and strength can depend on specimen geometry.

T M Keaveny1, R E Borchers, L J Gibson, W C Hayes.   

Abstract

We performed a series of uniaxial compression tests on wet bovine trabecular bone to compare both modulus and strength when measured using 2:1 aspect ratio (10 mm long, 5 mm diameter) cylinders (n = 30) and 5 mm cubes (n = 29). We also compared the correlation coefficients in the resulting modulus-density and strength-density regressions and the standard errors of the estimate. When comparing the mean values of modulus and strength for each group, the confounding variations in apparent density were accounted for with an analysis of covariance. The Fisher's Z transformation was used to compare the correlation coefficients statistically. Results from the analysis of covariance indicated that the modulus and strength of the cubes were higher by 36% (p < 0.01) and 18% (p < 0.05), respectively, with respect to the 2:1 cylinder values. The correlation coefficients in the modulus-density and strength-density regressions were not sensitive to the regression model (linear versus power law). However, correlation coefficients for both modulus-density and strength-density regressions were higher (p < 0.05) for the 2:1 cylinders (r = 0.90, modulus; r = 0.94, strength) than for the cubes (r = 0.57, modulus; r = 0.82, strength). In addition, the standard errors of the estimate in both modulus and strength were substantially lower for the 2:1 cylinders. These data indicate that both modulus and strength can depend on the specimen geometry when using conventional compression testing techniques. We conclude, therefore, that inter-study comparisons of modulus and strength may be invalid if these confounding effects of different specimen geometries are not addressed. Our data also indicate that density can better explain the observed variance in modulus and strength when 2:1 cylinders are used as opposed to cubes. Using this phenomenon as a rationale for choosing a standard specimen gometry, we recommend that the 2:1 cylinder be used as a standard specimen in studies designed to determine the effects of various treatments on the uniaxial compressive modulus and strength of trabecular bone.

Entities:  

Mesh:

Year:  1993        PMID: 8349722     DOI: 10.1016/0021-9290(93)90059-n

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Fractal-based image texture analysis of trabecular bone architecture.

Authors:  C Jiang; R E Pitt; J E Bertram; D J Aneshansley
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Fatigue characterization of a polymer foam to use as a cancellous bone analog material in the assessment of orthopaedic devices.

Authors:  V Palissery; M Taylor; M Browne
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

3.  Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation.

Authors:  Ardiyansyah Syahrom; Mohammed Rafiq Abdul Kadir; Jaafar Abdullah; Andreas Öchsner
Journal:  Med Biol Eng Comput       Date:  2011-09-24       Impact factor: 2.602

4.  Volumetric topological analysis: a novel approach for trabecular bone classification on the continuum between plates and rods.

Authors:  Punam K Saha; Yan Xu; Hong Duan; Anneliese Heiner; Guoyuan Liang
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

5.  Assessment of bone quality using finite element analysis based upon micro-CT images.

Authors:  Yumie Rhee; June-Huyck Hur; Ye-Yeon Won; Sung-Kil Lim; Myong-Hyun Beak; Wen-Quan Cui; Kwang-Gyoun Kim; Young Eun Kim
Journal:  Clin Orthop Surg       Date:  2009-02-06

6.  Characterization of porous hydroxyapatite.

Authors:  K A Hing; S M Best; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  1999-03       Impact factor: 3.896

Review 7.  A biomechanical sorting of clinical risk factors affecting osteoporotic hip fracture.

Authors:  Y Luo
Journal:  Osteoporos Int       Date:  2015-09-11       Impact factor: 4.507

8.  Human cancellous bone from T12-L1 vertebrae has unique microstructural and trabecular shear stress properties.

Authors:  Yener N Yeni; Do-Gyoon Kim; George W Divine; Evan M Johnson; Dianna D Cody
Journal:  Bone       Date:  2008-09-20       Impact factor: 4.398

9.  Compressive and tensile mechanical properties of the porcine nasal septum.

Authors:  Ayman A Al Dayeh; Susan W Herring
Journal:  J Biomech       Date:  2013-10-08       Impact factor: 2.712

10.  Relationship between mechanical properties and bone mineral density of human femoral bone retrieved from patients with osteoarthritis.

Authors:  Yvonne Haba; Tobias Lindner; Andreas Fritsche; Ann-Kristin Schiebenhöfer; Robert Souffrant; Daniel Kluess; Ralf Skripitz; Wolfram Mittelmeier; Rainer Bader
Journal:  Open Orthop J       Date:  2012-10-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.