Literature DB >> 8339630

Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake.

N Nakanishi1, T Yoshioka, Y Okano, T Nishimura.   

Abstract

To determine whether continuous Fick cardiac output measurement is applicable to exercise testing, cardiac output data obtained by the continuous Fick method (Qcf) during exercise were compared with data obtained by the thermodilution method (Qth). Seventeen patients with old myocardial infarction underwent a 1-min or 3-min incremental exercise test (protocols 1 and 2, respectively). During exercise, the oxygen consumption (VO2), arterial oxygen saturation (SaO2), and mixed venous oxygen saturation (SvO2) were monitored continuously. Qcf was calculated at 12-s intervals by the Fick equation. The SaO2 remained almost constant during exercise. The SvO2 showed four characteristic phases during exercise protocol 1. SvO2 values changed rapidly in phases 2 and 4, but only slightly during phase 3. In exercise protocol 2, SvO2 almost reached a steady-state by the end of each stage. The correlation between Qcf and Qth was good in protocol 1 (r = 0.86), except in phases 2 and 4, and was also good in protocol 2 (r = 0.80). We conclude that the continuous Fick method may be applicable for determining the cardiac output during exercise provided that the variation in SvO2 is slight.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8339630     DOI: 10.1378/chest.104.2.419

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

2.  Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements.

Authors:  David M Tehrani; Jonathan Grinstein; Sara Kalantari; Gene Kim; Nitasha Sarswat; Sirtaz Adatya; Gabriel Sayer; Nir Uriel
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

3.  Increased FIO2 influences SvO2 interpretation and accuracy of Fick-based cardiac output assessment in cardiac surgery patients: A prospective randomized study.

Authors:  Sheng-Yi Lin; Feng-Cheng Chang; Jr-Rung Lin; An-Hsun Chou; Yung-Fong Tsai; Chia-Chih Liao; Hsin-I Tsai; Chun-Yu Chen
Journal:  Medicine (Baltimore)       Date:  2021-09-10       Impact factor: 1.817

4.  The reliability of continuous measurement of mixed venous oxygen saturation during exercise in patients with chronic heart failure.

Authors:  Boudewijn T H M Sleutjes; Hareld M C Kemps; Eric J M Thijssen; Frans N van de Vosse; Goof Schep; Chris H Peters; Pieter F F Wijn
Journal:  Eur J Appl Physiol       Date:  2007-10-24       Impact factor: 3.078

Review 5.  Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.

Authors:  C F Wippermann; R G Huth; F X Schmidt; J Thul; M Betancor; D Schranz
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

Review 6.  Exercise Right Heart Catheterisation in Cardiovascular Diseases: A Guide to Interpretation and Considerations in the Management of Valvular Heart Disease.

Authors:  Felipe H Valle; Basma Mohammed; Stephen P Wright; Robert Bentley; Neil P Fam; Susanna Mak
Journal:  Interv Cardiol       Date:  2021-02-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.