Literature DB >> 8339426

Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device.

C Boutin1, N N Musewe, J F Smallhorn, J D Dyck, T Kobayashi, L N Benson.   

Abstract

BACKGROUND: Transcatheter device occlusion of atrial septal defects is an attractive approach, but its efficacy and place in patient management remain to be determined. METHODS AND
RESULTS: To evaluate the medium-term results of atrial septal defect device occlusion and factors influencing residual shunting, transesophageal and transthoracic echocardiograms of 49 patients were reviewed. Transesophageal echocardiograms on 48 patients immediately following surgical closure revealed residual shunting in 2% compared with 91% after device occlusion; this proportion decreased to 53% after a mean follow-up of 10 months. The actuarial analysis suggests a progressive resolution of shunting with time. One patient had residual shunting by transesophageal echocardiography immediately after surgical closure compared with 29 after a mean follow-up of 10 months after device occlusion. Residual shunting was not influenced by (1) dimension, location, or position with relation to the device as assessed by transesophageal echocardiography; (2) location of the defect; or (3) device size relative to the stretched dimension of the defect. In 15 patients, a poor correlation existed between transesophageal and transthoracic echocardiographic findings. Variability in serial transthoracic echocardiographic findings was observed in 14. Right ventricular dimension, heart size, and presence of a murmur at follow-up did not correlate with the presence or size of residual shunting after device occlusion.
CONCLUSIONS: These results suggest that ongoing spontaneous resolution of residual shunting occurs after device insertion. Factors related to the defect or device could not predict eventual resolution of residual shunting. Transthoracic echocardiography in the follow-up of these patients may not be reliable in determining presence of residual shunting.

Entities:  

Mesh:

Year:  1993        PMID: 8339426     DOI: 10.1161/01.cir.88.2.621

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  25 in total

1.  Interventional pediatric cardiology: device closures.

Authors:  J L Wilkinson
Journal:  Indian J Pediatr       Date:  2000-07       Impact factor: 1.967

2.  Improving migraine by means of primary transcatheter patent foramen ovale closure: long-term follow-up.

Authors:  Gianluca Rigatelli; Fabio Dell'avvocata; Paolo Cardaioli; Massimo Giordan; Gabriele Braggion; Silvio Aggio; Roberto L'erario; Mauro Chinaglia
Journal:  Am J Cardiovasc Dis       Date:  2012-05-20

3.  Closure of atrial septal defects by transcatheter devices.

Authors:  A G Magee; S A Qureshi
Journal:  Pediatr Cardiol       Date:  1997 Sep-Oct       Impact factor: 1.655

4.  Percutaneous closure of secundum atrial septal defect with a new self centering device ("angel wings").

Authors:  C Rickers; C Hamm; H Stern; T Hofmann; O Franzen; R Schräder; H Sievert; D Schranz; I Michel-Behnke; J Vogt; D Kececioglu; W Sebening; A Eicken; H Meyer; W Matthies; F Kleber; J Hug; J Weil
Journal:  Heart       Date:  1998-11       Impact factor: 5.994

5.  Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children.

Authors:  G Hausdorf; M Schneider; B Franzbach; C Kampmann; K Kargus; B Goeldner
Journal:  Heart       Date:  1996-01       Impact factor: 5.994

Review 6.  Interventional pediatric cardiology: state of the art and future perspective.

Authors:  W A Radtke
Journal:  Eur J Pediatr       Date:  1994-08       Impact factor: 3.183

Review 7.  [Interventions in congenital heart disease and their sequelae in adults].

Authors:  A A Schmaltz; U Neudorf; S Sack; O Galal
Journal:  Herz       Date:  1999-06       Impact factor: 1.443

8.  Transcatheter closure of atrial septal defects using the Cardio-Seal implant.

Authors:  C A Pedra; J Pihkala; K J Lee; C Boutin; D G Nykanen; P R McLaughlin; D A Harrison; R M Freedom; L Benson
Journal:  Heart       Date:  2000-09       Impact factor: 5.994

9.  Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings.

Authors:  A Lange; M Walayat; C M Turnbull; P Palka; P Mankad; G R Sutherland; M J Godman
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

10.  Device closure of secundum atrial septal defects in infants weighing less than 8 kg.

Authors:  Ram N Bishnoi; Allen D Everett; Richard E Ringel; Carl Y Owada; Ralf J Holzer; Joanne L Chisolm; Wolfgang A Radtke; D Scott Lim; John F Rhodes; John D Coulson
Journal:  Pediatr Cardiol       Date:  2014-04-11       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.