Literature DB >> 8334930

Refraction changes during elevation of intraocular pressure by suction cup, their reflection in the pattern visual evoked cortical potential and their compensation.

A Bernd1, W D Ulrich, H Teubel, F Rohrwacher, T Barth.   

Abstract

Visual evoked cortical potential studies using pattern stimuli with the intraocular pressure raised artificially by the suction cup method have been reported. Possible changes in the refraction of the eye due to the method employed and their influence on the pattern visual evoked cortical potential have not been considered. Changes in the refraction of the eye during artificial intraocular pressure elevation and the influence of such changes on pattern visual evoked cortical potentials were studied. The refraction changes were found to depend on the shape of the suction cup. They could be compensated for by employing properly shaped suction cups and contact lenses. The behavior of amplitude and latency of the pattern visual evoked cortical potential at artificially elevated intraocular pressure with compensation for refraction changes has been studied and found to depend in a characteristic manner on ocular perfusion pressure.

Mesh:

Year:  1993        PMID: 8334930     DOI: 10.1007/bf01206213

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  21 in total

1.  Visual evoked cortical potentials during pressure-blinding.

Authors:  R Fox; R Blake; J R Bourne
Journal:  Vision Res       Date:  1973-02       Impact factor: 1.886

2.  Refraction determined electrophysiologically. Responses to alternation of visual contours.

Authors:  M Millodot; L A Riggs
Journal:  Arch Ophthalmol       Date:  1970-09

3.  Effects of contour sharpness and check-size on visually evoked cortical potentials.

Authors:  M R Harter; C T White
Journal:  Vision Res       Date:  1968-06       Impact factor: 1.886

4.  Semiautomated suction ophthalmodynamometry.

Authors:  M A Galin; I Baras; J M Dodick
Journal:  Am J Ophthalmol       Date:  1969-08       Impact factor: 5.258

5.  [A test of pressure tolerance of the optic nerve head in ocular hypertension].

Authors:  L E Pillunat; R Stodtmeister; I Wilmanns; T Christ
Journal:  Klin Monbl Augenheilkd       Date:  1986-01       Impact factor: 0.700

6.  [Ocular autoregulation in primary wide angle glaucoma].

Authors:  W D Ulrich; C Ulrich; A Petzschmann; S Richter; A Ulrich
Journal:  Fortschr Ophthalmol       Date:  1988

7.  An electrophysiological approach to the diagnosis and treatment of glaucoma.

Authors:  W D Ulrich; C Ulrich
Journal:  Dev Ophthalmol       Date:  1984

Review 8.  Visually evoked potentials: theory, techniques and clinical applications.

Authors:  S Sokol
Journal:  Surv Ophthalmol       Date:  1976 Jul-Aug       Impact factor: 6.048

9.  [Modification of refraction and visual noise perception by suction cup oculocompression].

Authors:  U Schiefer; H Wilhelm; E Zrenner; E Aulhorn
Journal:  Fortschr Ophthalmol       Date:  1991

10.  [Total average values of transient visual evoked cortical potentials in tests of the pressure tolerance of the optic nerve].

Authors:  M Kaufmann; R Stodtmeister; L Pillunat; I Wilmanns
Journal:  Fortschr Ophthalmol       Date:  1990
View more
  2 in total

1.  New device for artificial increasing intraocular pressure.

Authors:  P R Preussner; A Duran
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-11       Impact factor: 3.117

2.  Influence of suction cup oculopression on corneal astigmatism.

Authors:  U Schiefer; C Ulrich; W D Ulrich; C Petzel; A Bernd; H Wilhelm
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-02       Impact factor: 3.117