Literature DB >> 8328672

Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay.

O Niwa1, Y Xu, H B Halsall, W R Heineman.   

Abstract

A small-volume voltammetric detection of 4-aminophenol (PAP) has been developed using an interdigitated array (IDA) microelectrode cell in order to apply the IDA to electrochemical enzyme immunoassay. The signal of PAP at the IDA was steady state, and its magnitude was amplified compared with that of the usual single electrode due to redox cycling of PAP between the two finger sets of the IDA. A linear relationship between PAP concentration and cathodic limiting current was obtained from 1 to 1000 microM, reproducibly. The minimum sample volume in the measurement was reduced to 800 nL. High sample throughput of less than 1-min detection time per sample was achieved on 2-10-microL PAP samples. This IDA cell was applied to the electrochemical enzyme immunoassay of mouse IgG. Alkaline phosphatase was used as the enzyme label. The mouse IgG concentration was evaluated by detecting the concentration of PAP, which is the product of enzymatic reaction of the substrate, 4-aminophenyl phosphate (PAPP). Anti-mouse IgG was covalently immobilized on the glass surface of the small-volume immunowells by carbodiimide coupling. The assay range was 10-1000 ng/mL using 10-microL sample and 20-microL substrate solutions.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8328672     DOI: 10.1021/ac00059a013

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Spatially and temporally resolved single-cell exocytosis utilizing individually addressable carbon microelectrode arrays.

Authors:  Bo Zhang; Kelly L Adams; Sarah J Luber; Daniel J Eves; Michael L Heien; Andrew G Ewing
Journal:  Anal Chem       Date:  2008-01-31       Impact factor: 6.986

2.  Redox-magnetohydrodynamic microfluidics without channels and compatible with electrochemical detection under immunoassay conditions.

Authors:  Melissa C Weston; Christena K Nash; Ingrid Fritsch
Journal:  Anal Chem       Date:  2010-09-01       Impact factor: 6.986

3.  High-sensitivity electrochemical enzyme-linked assay on a microfluidic interdigitated microelectrode.

Authors:  I-Jane Chen; Ian M White
Journal:  Biosens Bioelectron       Date:  2011-05-06       Impact factor: 10.618

4.  Redox cycling without reference electrodes.

Authors:  Sahana Sarkar; Klaus Mathwig; Shuo Kang; Ab F Nieuwenhuis; Serge G Lemay
Journal:  Analyst       Date:  2014-11-21       Impact factor: 4.616

5.  Polycaprolactone-enabled sealing and carbon composite electrode integration into electrochemical microfluidics.

Authors:  Kevin J Klunder; Kaylee M Clark; Cynthia McCord; Kathleen E Berg; Shelley D Minteer; Charles S Henry
Journal:  Lab Chip       Date:  2019-06-28       Impact factor: 6.799

6.  Nanoporous gold as a solid support for protein immobilization and development of an electrochemical immunoassay for prostate specific antigen and carcinoembryonic antigen.

Authors:  Binod Pandey; Alexei V Demchenko; Keith J Stine
Journal:  Mikrochim Acta       Date:  2012-10-01       Impact factor: 5.833

Review 7.  Multiplex Immunoassay Techniques for On-Site Detection of Security Sensitive Toxins.

Authors:  Christopher Pöhlmann; Thomas Elßner
Journal:  Toxins (Basel)       Date:  2020-11-20       Impact factor: 4.546

8.  Multichannel boron doped nanocrystalline diamond ultramicroelectrode arrays: design, fabrication and characterization.

Authors:  Raphael Kiran; Lionel Rousseau; Gaëlle Lissorgues; Emmanuel Scorsone; Alexandre Bongrain; Blaise Yvert; Serge Picaud; Pascal Mailley; Philippe Bergonzo
Journal:  Sensors (Basel)       Date:  2012-06-07       Impact factor: 3.576

  8 in total