Literature DB >> 21601441

High-sensitivity electrochemical enzyme-linked assay on a microfluidic interdigitated microelectrode.

I-Jane Chen1, Ian M White.   

Abstract

A novel enzyme-linked DNA hybridization assay on an interdigitated array (IDA) microelectrode integrated into a microfluidic channel is demonstrated with sub-nM detection limit. To improve the detection limit as compared to conventional electrochemical biosensors, a recyclable redox product, 4-aminophenol (PAP) is used with an IDA microelectrode. The IDA has a modest and easily fabricated inter-digit spacing of 10 μm, yet we were able to demonstrate 97% recycling efficiency of PAP due to the integration in a microfluidic channel. With a 70 nL sample volume, the characterized detection limit for PAP of 1.0 × 10⁻¹⁰ M is achieved, with a linear dynamic range that extends from 1.0 × 10⁻⁹ to 1.0 × 10⁻⁵ M. This detection limit, which is the lowest reported detection limit for PAP, is due to the increased sensitivity provided by the sample confinement in the microfluidic channel, as well as the increased repeatability due to perfectly static flow in the microchannel and an additional anti-fouling step in the protocol. DNA sequence detection is achieved through a hybridization sandwich of an immobilized complementary probe, the target DNA sequence, and a second complementary probe labeled with β-galactosidase (β-GAL); the β-GAL converts its substrate, 4-aminophenyl-d-galactopyranoside (PAPG), into PAP. In this report we present the lowest reported observed detection limit (1.0 × 10⁻¹⁰ M) for an enzyme-linked DNA hybridization assay using an IDA microelectrode and a redox signaling paradigm. Thus, we have demonstrated highly sensitive detection of a targeted DNA sequence using a low-cost easily fabricated electrochemical biosensor integrated into a microfluidic channel.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21601441      PMCID: PMC3120925          DOI: 10.1016/j.bios.2011.04.044

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  17 in total

1.  Small volume bead assay for ovalbumin with electrochemical detection.

Authors:  S Purushothama; S Kradtap; C A Wijayawardhana; H B Halsall; W R Heineman
Journal:  Analyst       Date:  2001-03       Impact factor: 4.616

Review 2.  Electrochemical immunoassays.

Authors:  A Warsinke; A Benkert; F W Scheller
Journal:  Fresenius J Anal Chem       Date:  2000 Mar-Apr

3.  Electrochemical enzyme immunoassays on microchip platforms.

Authors:  J Wang; A Ibáñez; M P Chatrathi; A Escarpa
Journal:  Anal Chem       Date:  2001-11-01       Impact factor: 6.986

4.  An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities.

Authors:  Jin-Woo Choi; Kwang W Oh; Jennifer H Thomas; William R Heineman; H Brian Halsall; Joseph H Nevin; Arthur J Helmicki; H Thurman Henderson; Chong H Ahn
Journal:  Lab Chip       Date:  2001-12-06       Impact factor: 6.799

5.  On-chip electric field driven electrochemical detection using a poly(dimethylsiloxane) microchannel with gold microband electrodes.

Authors:  Olga Ordeig; Neus Godino; Javier del Campo; Francesc Xavier Muñoz; Fredrik Nikolajeff; Leif Nyholm
Journal:  Anal Chem       Date:  2008-04-03       Impact factor: 6.986

6.  A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities.

Authors:  Jaephil Do; Chong H Ahn
Journal:  Lab Chip       Date:  2008-02-28       Impact factor: 6.799

7.  Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay.

Authors:  O Niwa; Y Xu; H B Halsall; W R Heineman
Journal:  Anal Chem       Date:  1993-06-01       Impact factor: 6.986

8.  Immobilization of DNA onto poly(dimethylsiloxane) surfaces and application to a microelectrochemical enzyme-amplified DNA hybridization assay.

Authors:  Daojun Liu; Robbyn K Perdue; Li Sun; Richard M Crooks
Journal:  Langmuir       Date:  2004-07-06       Impact factor: 3.882

9.  Fast electrochemical detection of anti-HIV antibodies: coupling allosteric enzymes and disk microelectrode arrays.

Authors:  Olivier Laczka; Rosa María Ferraz; Neus Ferrer-Miralles; Antonio Villaverde; Francesc Xavier Muñoz; F Javier del Campo
Journal:  Anal Chim Acta       Date:  2009-03-17       Impact factor: 6.558

10.  Adsorptive stripping voltammetric determination of 4-aminophenol at a single-wall carbon nanotubes film coated electrode.

Authors:  Wensheng Huang; Weibing Hu; Jinchun Song
Journal:  Talanta       Date:  2003-11-04       Impact factor: 6.057

View more
  4 in total

1.  Single Microfluidic Electrochemical Sensor System for Simultaneous Multi-Pulmonary Hypertension Biomarker Analyses.

Authors:  GeonHui Lee; JuKyung Lee; JeongHoon Kim; Hak Soo Choi; Jonghan Kim; SangHoon Lee; HeaYeon Lee
Journal:  Sci Rep       Date:  2017-08-08       Impact factor: 4.379

Review 2.  Lab-on-chip systems for integrated bioanalyses.

Authors:  João Pedro Conde; Narayanan Madaboosi; Ruben R G Soares; João Tiago S Fernandes; Pedro Novo; Geraud Moulas; Virginia Chu
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

3.  Enzyme-modified indium tin oxide microelectrode array-based electrochemical uric acid biosensor.

Authors:  Nidhi Puri; Vikash Sharma; Vinod K Tanwar; Nahar Singh; Ashok M Biradar
Journal:  Prog Biomater       Date:  2013-02-22

4.  Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications.

Authors:  Daniel T Bacheschi; Evan Z Strittmatter; Sonya Sawtelle; Mohsen Nami
Journal:  Micromachines (Basel)       Date:  2022-01-17       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.