Literature DB >> 8327713

CT-guided bone biopsy performed by means of a coaxial biopsy system with an eccentric drill.

K H Ahlström1, K G Aström.   

Abstract

Thirty-seven consecutive bone biopsies guided with computed tomography were performed in 32 patients by use of three different techniques to penetrate cortical bone and gain access to the lesion. The following instruments were used: a thin bone biopsy needle (12 biopsies), a conventional drill with an outer cannula (six biopsies), and a coaxial biopsy system that consists of a drill with an eccentric tip and an outer cannula (19 biopsies). This eccentric drill makes a hole in the bone larger than the diameter of the cannula and thereby makes it easy to advance the cannula over the drill until the cannula is anchored in the bone. One can then obtain multiple samples through the cannula. The thin bone biopsy needle could not penetrate thick (8 mm thick) cortical bone. The outer cannula was not anchored in the bone when the conventional drill was used. In 16 biopsies, the new coaxial biopsy system penetrated cortical bone with a thickness of 1-8 mm and was anchored there, and lesion samples were obtained through the anchored cannula.

Entities:  

Mesh:

Year:  1993        PMID: 8327713     DOI: 10.1148/radiology.188.2.8327713

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

Review 1.  Radiological diagnosis of skeletal metastases.

Authors:  V Söderlund
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

2.  Multiple fine-needle biopsies using a coaxial technique: efficacy and a comparison of three methods.

Authors:  K D Hopper; C S Abendroth; T R TenHave; J Hartzel; C A Savage
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Sep-Oct       Impact factor: 2.740

Review 3.  Percutaneous bone biopsy, techniques and indications.

Authors:  W Berning; J Freyschmidt; H Ostertag
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Using a powered bone marrow biopsy system results in shorter procedures, causes less residual pain to adult patients, and yields larger specimens.

Authors:  James R Berenson; Ori Yellin; Brent Blumenstein; Deanna Bojanower; Jonathan Croopnick; David Aboulafia; Gargi Upadhyaya; Cathy Spadaccini
Journal:  Diagn Pathol       Date:  2011-03-23       Impact factor: 2.644

5.  Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices.

Authors:  Larry J Miller; Thomas E Philbeck; Diana F Montez; Tatiana A Puga; Kim E Brodie; Stephen C Cohen; Cathy Spadaccini; Ronan Swords; Andrew J Brenner
Journal:  Hematol Rep       Date:  2011-06-18

6.  Differences in Radiation Exposure of CT-Guided Percutaneous Manual and Powered Drill Bone Biopsy.

Authors:  Sebastian Zensen; Sumitha Selvaretnam; Marcel Opitz; Denise Bos; Johannes Haubold; Jens Theysohn; Michael Forsting; Nika Guberina; Axel Wetter
Journal:  Cardiovasc Intervent Radiol       Date:  2021-05-11       Impact factor: 2.740