Literature DB >> 8314824

Fibroblast response to metallic debris in vitro. Enzyme induction cell proliferation, and toxicity.

W J Maloney1, R L Smith, F Castro, D J Schurman.   

Abstract

Bovine synovial fibroblasts in primary monolayer culture were exposed to particulate metallic debris. The effects of the metallic particles on the synthesis and secretion of proteolytic enzymes and on cell proliferation and viability were examined. Uniform suspensions of titanium, titanium-aluminum, cobalt, and chromium particles, ranging in size from approximately 0.1 to ten micrometers (average, one to three micrometers), were prepared; the particle concentrations (the volume of particles divided by the total volume of the suspension) ranged from 0.0005 to 5 per cent. Aliquots of the particle suspensions were added to the synovial fibroblast cultures. The final particle concentrations in the media ranged from 0.0000083 to 0.83 per cent. After seventy-two hours of exposure, each medium was harvested and was assayed for proteolytic and collagenolytic activity and for hexosaminidase levels. Neutral metalloproteases, quantified by collagenolytic and caseinolytic (proteolytic) activity, represent enzymes, secreted by cells, that are capable of degrading extracellular matrix. Hexosaminidase is a marker for lysosomal enzyme activity that can include more than thirty enzymes, such as proteases, lipases, nucleases, and phosphatases. Cell proliferation was quantified by uptake of 3H-thymidine. Cell morphology was examined by scanning electron microscopy. Titanium, titanium-aluminum, and chromium significantly stimulated 3H-thymidine uptake at low particle concentrations (p < 0.01, p < 0.002, and p < 0.002, respectively). Exposure to cobalt, even at the lowest particle concentration, resulted in a significant decrease in thymidine uptake (p = 0.027). At the highest particle concentrations, all particles were toxic, as evidenced by the absence of thymidine uptake. At high particle concentrations, all of the metals caused a decrease in caseinolytic (proteolytic) and collagenolytic activity in the culture media. Titanium elevated the lysosomal enzyme marker, hexosaminidase, except at high concentrations. Chromium and titanium-aluminum had no significant effect on hexosaminidase at any particle concentration, while cobalt decreased all enzyme markers at mid-particle to high-particle concentrations. Scanning electron microscopy demonstrated that the morphological response of fibroblasts to titanium included membrane-ruffling and extension of filopodia, typical of active fibroblasts. In contrast, exposure to cobalt at the same concentration resulted in cell crenation, indicative of cell death.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8314824     DOI: 10.2106/00004623-199306000-00005

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

1.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

Authors:  J L Tipper; P J Firkins; E Ingham; J Fisher; M H Stone; R Farrar
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

Review 2.  Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature.

Authors:  Lena Katharina Müller-Heupt; Eik Schiegnitz; Sebahat Kaya; Elisabeth Jacobi-Gresser; Peer Wolfgang Kämmerer; Bilal Al-Nawas
Journal:  Int J Implant Dent       Date:  2022-07-11

3.  Biodistribution of titanium dioxide from biologic compartments.

Authors:  Daniel G Olmedo; Deborah R Tasat; María Beatriz Guglielmotti; Rómulo Luis Cabrini
Journal:  J Mater Sci Mater Med       Date:  2008-04-04       Impact factor: 3.896

4.  Amino alcohol-based degradable poly(ester amide) elastomers.

Authors:  Christopher J Bettinger; Joost P Bruggeman; Jeffrey T Borenstein; Robert S Langer
Journal:  Biomaterials       Date:  2008-03-04       Impact factor: 12.479

5.  An in vitro screening assay for inhibitors of proinflammatory mediators in herbal extracts using human synoviocyte cultures.

Authors:  Carmelita G Frondoza; Afshin Sohrabi; Anna Polotsky; Phong V Phan; David S Hungerford; Lars Lindmark
Journal:  In Vitro Cell Dev Biol Anim       Date:  2004 Mar-Apr       Impact factor: 2.416

6.  The study of metal ion release and cytotoxicity in Co-Cr-Mo and Ti-Al-V alloy in total knee prosthesis - scanning electron microscopic observation.

Authors:  Shizuko Ichinose; Takeshi Muneta; Ichiro Sekiya; Soichiro Itoh; Hideki Aoki; Motoki Tagami
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

7.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

8.  DEBS - a unification theory for dry eye and blepharitis.

Authors:  James M Rynerson; Henry D Perry
Journal:  Clin Ophthalmol       Date:  2016-12-09

9.  Metal-on-Metal Hip Retrieval Analysis: A Case Report.

Authors:  Thomas B Pace; Kara A Rusaw; Lawrence J Minette; Brayton R Shirley; Rebecca G Snider; John D Desjardins
Journal:  Case Rep Orthop       Date:  2013-06-09

10.  Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells.

Authors:  N Coen; M A Kadhim; E G Wright; C P Case; C E Mothersill
Journal:  Br J Cancer       Date:  2003-02-24       Impact factor: 7.640

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.