Literature DB >> 8310478

Electronic verification of donor-recipient compatibility: the computer crossmatch.

S H Butch1, W J Judd, E A Steiner, M Stoe, H A Oberman.   

Abstract

BACKGROUND: This article describes standard operating procedures (SOPs) for a computer crossmatch to replace the immediate-spin crossmatch for ABO incompatibility between patient blood samples submitted for pretransfusion testing and the blood component selected for transfusion. These SOPs were developed following recent changes to the Standards for Blood Banks and Transfusion Services of the American Association of Blood Banks (AABB). STUDY DESIGN AND METHODS: SOPs were developed, utilizing currently available software, for pretransfusion testing. The SOP for donor unit processing entails bar code entry of the unit number, component name, and ABO/Rh type; computer entry and interpretation of serologic reactions; warning of discrepancies between bar code-entered blood type and result interpretation; and quarantine of the donor unit in such instances. The SOP for patient sample testing requires bar code entry of specimen accession number, which accesses patient demographics; computer entry and interpretation of ABO/Rh tests; repeat blood typing at the time of crossmatch if only one patient blood type is on record; and warning if there are nonconcordant current and historical blood types. The computer crossmatch SOP requires bar code entry of specimen accession and donor unit numbers; release of group O red cells pending resolution of discrepancies; and immediate-spin crossmatch during computer downtime. Tables validated on-site prompt warning messages and prevent both computer crossmatch and release if blood components of the wrong ABO type are selected.
RESULTS: These SOPs meet the requirements of the 15th edition of the AABB Standards. Projected annual time savings at this institution are > 100,000 workload recording units. Further benefits include reduced patient sample volume requirements, less handling of biohazardous material, and elimination of unwanted positive or negative reactions associated with the immediate-spin crossmatch. Release of incompatible blood components when the wrong patient blood type is on record is addressed by requiring the use of group O red cells in the absence of two concordant blood types, one of which must be from a current sample.
CONCLUSION: A combination of existing computer programs and carefully developed SOPs can provide a safe and efficient means of detecting donor-recipient incompatibility without performance of serologic crossmatch.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8310478     DOI: 10.1046/j.1537-2995.1994.34294143935.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  8 in total

Review 1.  Is it time to give up the crossmatch?

Authors:  J P Wallis
Journal:  J Clin Pathol       Date:  2000-09       Impact factor: 3.411

2.  Cost-Effectiveness of Routine Type and Screens in Select Endonasal Skull Base Surgeries.

Authors:  Aviv Spillinger; Meredith Allen; Patrick Karabon; Houmehr Hojjat; Kerolos Shenouda; Inaya Hajj Hussein; Jeffrey T Jacob; Peter F Svider; Adam J Folbe
Journal:  J Neurol Surg B Skull Base       Date:  2021-05-31

3.  Transfusion management using a remote-controlled, automated blood storage.

Authors:  Pasqualepaolo Pagliaro; Rosalia Turdo
Journal:  Blood Transfus       Date:  2008-04       Impact factor: 3.443

4.  ABO, D blood typing and subtyping using plug-based microfluidics.

Authors:  Timothy R Kline; Matthew K Runyon; Mohammad Pothiawala; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2008-07-23       Impact factor: 6.986

5.  Virtual blood bank.

Authors:  Kit Fai Wong
Journal:  J Pathol Inform       Date:  2011-01-24

6.  Contemporary issues in transfusion medicine informatics.

Authors:  Gaurav Sharma; Anil V Parwani; Jay S Raval; Darrell J Triulzi; Richard J Benjamin; Liron Pantanowitz
Journal:  J Pathol Inform       Date:  2011-01-07

7.  Automation in Blood Centre: Its impact on Blood Safety.

Authors:  Snehalata C Gupte
Journal:  Asian J Transfus Sci       Date:  2015-04

8.  Safety issues related to the electronic cross-matching of blood in mainland China: A prospective cohort study involving cross-matching of 40,228 blood samples.

Authors:  Yuan-Jie Wang; Jia-Rui Liu; Yong Liu
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

  8 in total