Literature DB >> 8310154

An algorithm for automatic analysis of portal images: clinical evaluation for prostate treatments.

K G Gilhuijs1, A A el-Gayed, M van Herk, R E Vijlbrief.   

Abstract

The aim of this study is to assess the clinical value of an algorithm for automatic analysis of portal images by measuring the method's performance in a clinical study of treatment of prostate cancer. The algorithm is based on chamfer matching and measures displacements of patients relative to prescribed radiation beam positions. In this paper we propose a method to quantify the mean standard deviation (MSD) of the performance of automatic analysis relative to the MSD of the performance of trained radiographers using the clinical data set only, i.e. without using additional phantoms or simulations. The clinical data set in this study consists of 99 regional AP prostate images of 15 different patients. To assess the performance the automatic analysis in relation to that of the human observers, we studied the results of the unsupervised automatic analysis, as well as the results of a less-trained human observer and a well-trained human observer assisted by the automatic analysis (in this combination, automatic analysis is done first and the result is modified by the well-trained observer if the observer does not agree). First, the intra-observer variations of the well-trained observer are measured by repetitive analysis of a small subset of the clinical data. The distribution of differences in analysis between two arbitrary observers is described by the chi 2 distribution, and is tabulated in literature. We define the agreement histogram of an observer O as an estimator for the chi 2 distribution between O and the well-trained human observer, parameterized by the ratio of the intra-observer variations of O and the well-trained observer.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8310154     DOI: 10.1016/0167-8140(93)90256-8

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  5 in total

1.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction.

Authors:  James M Balter; Larry E Antonuk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

4.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

5.  A line-profile based double partial fusion method for acquiring planning CT of oversized patients in radiation treatment.

Authors:  Huanmei Wu; Qingya Zhao; Minsong Cao; Indra Das
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.