Literature DB >> 8301112

Short report: ambulatory blood pressure in normotensive compared with hypertensive subjects. The Ad-Hoc Working Group.

J A Staessen1, E T O'Brien, N Atkins, A K Amery.   

Abstract

OBJECTIVE: To delineate more precisely an operational threshold for making clinical decisions based on ambulatory blood pressure (ABP) measurement by studying the ABP in subjects who were diagnosed as either normotensive or hypertensive by conventional blood pressure (CBP) measurement.
SUBJECTS: Twenty-four research groups recruited 7069 subjects. Of these, 4577 were normotensive (CBP < or = 140/90 mmHg), 719 were borderline hypertensive (systolic CBP 141-159 mmHg or diastolic CBP 91-94 mmHg) and 1773 were definitely hypertensive. Of the subjects in the last of these categories, 1324 had systolic hypertension (systolic CBP > or = 160 mmHg) and 1310 had diastolic hypertension (diastolic CBP > or = 95 mmHg). Hypertension had been diagnosed from the mean of two to nine (median two) CBP measurements obtained at one to three (median two) visits.
RESULTS: The 95th centiles of the 24-h ABP distributions in the normotensive subjects were (systolic and diastolic, respectively) 133 and 82 mmHg. Of the subjects with systolic hypertension, 24% had 24-h systolic ABP < 133 mmHg. Similarly, 30% of those with diastolic hypertension had 24-h diastolic ABP < 82 mmHg. The probability that hypertensive subjects had 24-h ABP below these thresholds tended to increase with age and was two- to fourfold greater if the CBP of the subject had been measured at only one visit and if fewer than three CBP measurements had been averaged for establishing the diagnosis of hypertension. By contrast, for each 10-mmHg increment in systolic CBP, this probability decreased by 54% for 24-h systolic ABP and by 26% for 24-h diastolic ABP, and for each 5-mmHg increment in diastolic CBP it decreased by 6 and 9%, respectively.
CONCLUSIONS: The ABP distributions of the normotensive subjects included in the present international database were not materially different from those in previous reports in the literature. One-fifth to more than one-third of hypertensive subjects had an ABP which was below the 95th centile of the ABP of normotensive subjects, but this proportion decreased if the hypertensive subjects had shown a higher CBP upon repeated measurement. The prognostic implications of elevated CBP in the presence of normal ABP remain to be determined.

Entities:  

Mesh:

Year:  1993        PMID: 8301112

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  13 in total

1.  Blood pressure measurement in epidemiological investigations in teenagers.

Authors:  Y Coppieters; F Parent; L Berghmans; I Godin; A Levêque
Journal:  Eur J Epidemiol       Date:  2001       Impact factor: 8.082

2.  Coronary flow reserve is preserved in white-coat hypertension.

Authors:  D Erdogan; H Gullu; M Caliskan; I Yildirim; D Tok; H Muderrisoglu
Journal:  Heart       Date:  2005-12-30       Impact factor: 5.994

Review 3.  Obstructive sleep apnea and ambulatory blood pressure monitoring: current evidence and research gaps.

Authors:  Andrea Pio-Abreu; Heitor Moreno; Luciano F Drager
Journal:  J Hum Hypertens       Date:  2021-01-07       Impact factor: 3.012

4.  Predictive value of ambulatory blood pressure shortly after withdrawal of antihypertensive drugs in primary care patients.

Authors:  F W Beltman; W F Heesen; R H Kok; A J Smit; J F May; P A de Graeff; T K Havinga; F H Schuurman; E van der Veur; K I Lie; B Meyboom-de Jong
Journal:  BMJ       Date:  1996-08-17

Review 5.  Modern approaches to blood pressure measurement.

Authors:  J A Staessen; E T O'Brien; L Thijs; R H Fagard
Journal:  Occup Environ Med       Date:  2000-08       Impact factor: 4.402

6.  Preventing misdiagnosis of ambulatory hypertension: algorithm using office and home blood pressures.

Authors:  Daichi Shimbo; Sujith Kuruvilla; Donald Haas; Thomas G Pickering; Joseph E Schwartz; William Gerin
Journal:  J Hypertens       Date:  2009-09       Impact factor: 4.844

7.  Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

Authors:  Gianfranco Parati; Stefano Omboni; Paolo Palatini; Damiano Rizzoni; Grzegorz Bilo; Mariaconsuelo Valentini; Enrico Agabiti Rosei; Giuseppe Mancia
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-01-22

8.  A meta-analysis that helps clarify the use of automated office blood pressure in clinical practice.

Authors:  Martin G Myers
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-03-04       Impact factor: 3.738

9.  Office blood pressure is lower than awake ambulatory blood pressure at lower targets for treatment.

Authors:  Martin G Myers; Janusz Kaczorowski
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-09-24       Impact factor: 3.738

Review 10.  Systolic hypertension in the elderly: pushing the frontiers of therapy--a suggested new approach.

Authors:  Gordon S Stokes
Journal:  J Clin Hypertens (Greenwich)       Date:  2004-04       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.