Literature DB >> 8298927

Haemostasis after partial hepatectomy using argon beam coagulation.

R R Postema1, P W Plaisier, F J ten Kate, O T Terpstra.   

Abstract

The argon beam coagulator is a new device for haemostasis during and after surgery on parenchymatous organs. No data are available on its efficacy and tissue effect following hepatic resection. Blood loss, the time needed to achieve adequate haemostasis and histological findings after liver resection were assessed in 12 pigs using argon beam coagulation or suture ligation only, the mattress suture technique and tissue glue application. The treatment was randomly assigned to each of the four liver lobes in each pig. Median blood loss following argon beam coagulation was 13 (range 2-47) ml and after simple suture ligation 55 (range 2-260) ml (P < 0.02). The median time needed for adequate haemostasis following argon beam coagulation was 3 (range 2-7) min versus 14 (range 2-48) min in the control group (P < 0.005). There was no difference between argon beam coagulation and tissue glue, which were both superior to the use of mattress sutures. Argon beam coagulation resulted in less tissue damage than tissue glue or mattress suturing. The argon beam coagulator is an efficient device for achieving haemostasis following partial hepatectomy in the pig. It causes only a moderate tissue reaction.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8298927     DOI: 10.1002/bjs.1800801224

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  12 in total

1.  Hemostasis of the liver, spleen, and bone achieved by electrocautery greased with lidocaine gel.

Authors:  Andy Petroianu
Journal:  Surg Today       Date:  2011-01-26       Impact factor: 2.549

2.  Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial.

Authors:  Andrea Frilling; Gregor A Stavrou; Hans-Jörg Mischinger; Bernard de Hemptinne; Mogens Rokkjaer; Jürgen Klempnauer; Anders Thörne; Beat Gloor; Susanne Beckebaum; Mohamed F A Ghaffar; Christoph E Broelsch
Journal:  Langenbecks Arch Surg       Date:  2005-02-19       Impact factor: 3.445

3.  Two-surgeon technique for hepatic parenchymal transection of the noncirrhotic liver using saline-linked cautery and ultrasonic dissection.

Authors:  Thomas A Aloia; Daria Zorzi; Eddie K Abdalla; Jean-Nicolas Vauthey
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

4.  Argon beam coagulation as an adjunct in breast-conserving surgery.

Authors:  P Ridings; C Bailey; T E Bucknall
Journal:  Ann R Coll Surg Engl       Date:  1998-01       Impact factor: 1.891

5.  Practical usefulness of ultrasonic surgical aspirator with argon beam coagulation for hepatic parenchymal transection.

Authors:  Yasuhiko Nagano; Kenichi Matsuo; Chikara Kunisaki; Hideyuki Ike; Toshio Imada; Kuniya Tanaka; Shinji Togo; Hiroshi Shimada
Journal:  World J Surg       Date:  2005-07       Impact factor: 3.352

6.  Water-jet dissection for parenchymal division during hepatectomy.

Authors:  Charles M Vollmer; Elijah Dixon; Ajay Sahajpal; Mark S Cattral; David R Grant; Steven Gallinger; Bryce R Taylor; Paul D Greig
Journal:  HPB (Oxford)       Date:  2006       Impact factor: 3.647

7.  Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver.

Authors:  Ana Navarro; Fernando Burdio; Enrique J Berjano; Antonio Güemes; Ramón Sousa; Maria Rufas; Jorge Subirá; Ana Gonzalez; Jose M Burdío; Tomás Castiella; Eloy Tejero; Miguel A De Gregorio; Luis Grande; Ricardo Lozano
Journal:  Surg Endosc       Date:  2008-03-06       Impact factor: 4.584

8.  A new application for argon beam coagulation: the thymoma patient with pleural recurrence.

Authors:  Yen-Chiang Tseng; Yen-Han Tseng; En-Kuei Tang; Yih-Gang Goan
Journal:  J Thorac Dis       Date:  2018-05       Impact factor: 2.895

9.  Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments.

Authors:  Fernando Burdío; Enrique J Berjano; Ana Navarro; José M Burdío; Luis Grande; Ana Gonzalez; Ignacio Cruz; Antonio Güemes; Ramón Sousa; Jorge Subirá; Tomás Castiella; Ignasi Poves; Juan L Lequerica
Journal:  Biomed Eng Online       Date:  2009-03-18       Impact factor: 2.819

10.  Evaluation of a newly developed piezo actuator-driven pulsed water jet system for liver resection in a surviving swine animal model.

Authors:  Chikashi Nakanishi; Toru Nakano; Atsuhiro Nakagawa; Chiaki Sato; Masato Yamada; Naoki Kawagishi; Teiji Tominaga; Noriaki Ohuchi
Journal:  Biomed Eng Online       Date:  2016-01-25       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.