Literature DB >> 8296690

Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries.

I De Scheerder1, F De Man, M C Herregods, K Wilczek, L Barrios, E Raymenants, W Desmet, H De Geest, J Piessens.   

Abstract

Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.

Entities:  

Mesh:

Year:  1994        PMID: 8296690     DOI: 10.1016/0002-8703(94)90110-4

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  19 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

Review 2.  Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler.

Authors:  David E Newby; Keith A A Fox
Journal:  Br J Clin Pharmacol       Date:  2002-06       Impact factor: 4.335

Review 3.  Intravascular imaging tools in the cardiac catheterization laboratory: comprehensive assessment of anatomy and physiology.

Authors:  Parham Eshtehardi; Jennifer Luke; Michael C McDaniel; Habib Samady
Journal:  J Cardiovasc Transl Res       Date:  2011-04-01       Impact factor: 4.132

4.  Comparison of QCA systems.

Authors:  U Dietz; H J Rupprecht; R Brennecke; H P Fritsch; J Woltmann; S Blankenberg; J Meyer
Journal:  Int J Card Imaging       Date:  1997-08

5.  Correlation between dual-axis rotational coronary angiography and intravascular ultrasound in a coronary lesion assessment.

Authors:  Zhi-Geng Jin; Zhuo-Qi Zhang; Li-Min Jing; Yu-Jie Wei; Jiao Zhang; Jian-Ping Luo; Sheng-Li Yang; Dong-Xing Ma; Ying Liu; Wei Han; Yong Yang; Hui-Liang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-11       Impact factor: 2.357

Review 6.  Intracoronary ultrasound: current state of the art.

Authors:  P P Kearney; I R Starkey; G R Sutherland
Journal:  Br Heart J       Date:  1995-05

7.  Adenosine provokes diastolic dysfunction in microvascular angina.

Authors:  D Vinereanu; A G Fraser; M Robinson; A Lee; A Tweddel
Journal:  Postgrad Med J       Date:  2002-01       Impact factor: 2.401

8.  Lesion characteristics of acute myocardial infarction: an investigation with intravascular ultrasound.

Authors:  D Fukuda; T Kawarabayashi; A Tanaka; Y Nishibori; H Taguchi; Y Nishida; K Shimada; J Yoshikawa
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

9.  Glycaemic status influences the nature and severity of coronary artery disease.

Authors:  C Berry; S Noble; J C Grégoire; R Ibrahim; S Levesquie; M-A Lavoie; P L L'Allier; J-C Tardif
Journal:  Diabetologia       Date:  2010-01-14       Impact factor: 10.122

10.  Coronary angiographic scoring systems: an evaluation of their equivalence and validity.

Authors:  Ian J Neeland; Riyaz S Patel; Parham Eshtehardi; Saurabh Dhawan; Michael C McDaniel; S Tanveer Rab; Viola Vaccarino; A Maziar Zafari; Habib Samady; Arshed A Quyyumi
Journal:  Am Heart J       Date:  2012-10       Impact factor: 4.749

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.