Literature DB >> 8280982

Frequency response to retrospectively gated phase-contrast MR imaging: effect of interpolation.

R Frayne1, B K Rutt.   

Abstract

Retrospectively gated phase-contrast (PC) magnetic resonance velocity and volume flow measurements were evaluated in both in vitro and in vivo experiments. The accuracy of these measurements was found to be affected by the interpolation window width required in the reconstruction of retrospectively gated data. Interpolation modified the frequency content of the series of temporal measurements by decreasing the response at higher frequencies. With a series of sinusoidal flow waveforms, the frequency response of one specific implementation of retrospectively gated PC velocity measurements was experimentally determined. The experimental response agreed with the theoretical response predicted from an analysis of the interpolating function (2.2% root-mean-square difference). In vitro experiments with a simulated carotid flow waveform demonstrated errors in the systolic measurements that were a direct result of the modified frequency response. A volunteer study was also undertaken and confirmed the in vitro findings.

Mesh:

Year:  1993        PMID: 8280982     DOI: 10.1002/jmri.1880030619

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius.

Authors:  Yudy Natalia Flórez; David Moratal; Juana Forner; Luis Martí-Bonmatí; Estanislao Arana; Ulises Guajardo-Hernández; José Millet-Roig
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

2.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

3.  Characterization of volumetric flow rate waveforms at the carotid bifurcations of older adults.

Authors:  Yiemeng Hoi; Bruce A Wasserman; Yuanyuan J Xie; Samer S Najjar; Luigi Ferruci; Edward G Lakatta; Gary Gerstenblith; David A Steinman
Journal:  Physiol Meas       Date:  2010-01-20       Impact factor: 2.833

4.  On the optimal temporal resolution for phase contrast cardiovascular magnetic resonance imaging: establishment of baseline values.

Authors:  Francesco Santini; Michele Pansini; Maja Hrabak-Paar; Denise Yates; Thomas H Langenickel; Jens Bremerich; Oliver Bieri; Tilman Schubert
Journal:  J Cardiovasc Magn Reson       Date:  2020-10-05       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.