Literature DB >> 8278830

Noninvasive measurement of cervical tri-planar motion in normal subjects.

T Mayer1, S Brady, E Bovasso, P Pope, R J Gatchel.   

Abstract

An electronic digital inclinometer was used to obtain normative data on cervical mobility from 58 normal subjects. They consisted of 28 males (age range, 17-61) and 30 females (age range, 19-62). The measurements were taken from occiput to T1 in flexion-extension, lateral bend, and axial rotation, isolating the regional motion by measuring simultaneously the upper and lower margins of the eight mobile segments. A comparison of radiographs and inclinometer measures showed excellent correlations (r < 0.9997, P < 0.05). Normative data are presented. Gender-specific regional mobility differences occurred only in cervical extension, whereas no consistent age-related differences were found. Stiffer individuals could be found in either gender or any age group, but rigidity in one plane did not necessarily predict rigidity in another.

Entities:  

Mesh:

Year:  1993        PMID: 8278830     DOI: 10.1097/00007632-199311000-00007

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  10 in total

1.  A 3D motion analysis study comparing the effectiveness of cervical spine orthoses at restricting spinal motion through physiological ranges.

Authors:  Nicholas Rhys Evans; Georgina Hooper; Rachel Edwards; Gemma Whatling; Valerie Sparkes; Cathy Holt; Sashin Ahuja
Journal:  Eur Spine J       Date:  2013-01-04       Impact factor: 3.134

2.  Three-dimensional analysis of cervical spine motion: reliability of a computer assisted magnetic tracking device compared to inclinometer.

Authors:  Ioannis D Gelalis; Louis E DeFrate; Kosmas S Stafilas; Emilios E Pakos; James D Kang; Lars G Gilbertson
Journal:  Eur Spine J       Date:  2008-12-19       Impact factor: 3.134

3.  Immediate effects of inhibitive distraction on active range of cervical flexion in patients with neck pain: a pilot study.

Authors:  Kristín Briem; Peter Huijbregts; Maria Thorsteinsdottir
Journal:  J Man Manip Ther       Date:  2007

4.  Parabrachial nucleus neuronal responses to off-vertical axis rotation in macaques.

Authors:  Cyrus H McCandless; Carey D Balaban
Journal:  Exp Brain Res       Date:  2009-12-29       Impact factor: 1.972

5.  Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants.

Authors:  Yannick Tousignant-Laflamme; Nicolas Boutin; Alexandre M Dion; Carol-Anne Vallée
Journal:  J Neuroeng Rehabil       Date:  2013-07-05       Impact factor: 4.262

6.  Short Term Outcomes Following Open Reduction Internal Fixation Surgery for a Distal Radius Fracture: 2 Week Versus 4 Week Immobilization. A Retrospective Analysis.

Authors:  Angela Toemen; Shirley Collocott; Wolfgang Heiss-Dunlop
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-03-25

7.  Reliability of measuring the cervical sagittal translation mobility with a simple method in a clinical setting.

Authors:  Yvonne Severinsson; Lena Elisson; Olle Bunketorp
Journal:  Rehabil Res Pract       Date:  2012-11-04

8.  The effects of the Mulligan Sustained Natural Apophyseal Glide (SNAG) mobilisation in the lumbar flexion range of asymptomatic subjects as measured by the Zebris CMS20 3-D motion analysis system.

Authors:  Maria Moutzouri; Evdokia Billis; Nikolaos Strimpakos; Polixeni Kottika; Jacqueline A Oldham
Journal:  BMC Musculoskelet Disord       Date:  2008-10-01       Impact factor: 2.362

9.  Effects of diaphragm stretching on posterior chain muscle kinematics and rib cage and abdominal excursion: a randomized controlled trial.

Authors:  Francisco J González-Álvarez; Marie C Valenza; Irene Torres-Sánchez; Irene Cabrera-Martos; Janet Rodríguez-Torres; Yolanda Castellote-Caballero
Journal:  Braz J Phys Ther       Date:  2016-06-16       Impact factor: 3.377

10.  An Inexpensive and Easy to Use Cervical Range of Motion Measurement Solution Using Inertial Sensors.

Authors:  Rafael Raya; Rodrigo Garcia-Carmona; Cristina Sanchez; Eloy Urendes; Oscar Ramirez; Alvaro Martin; Abraham Otero
Journal:  Sensors (Basel)       Date:  2018-08-07       Impact factor: 3.576

  10 in total