Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures.

G A Rooke1, T A Bowdle.   

Abstract

Syringe pumps for vasoactive infusions have the advantages of small size and weight, portability, and low cost of the disposable components. However, limited syringe capacity necessitates the use of high drug concentrations, and the accidental delivery of even a small volume of infusate could seriously alter the patient's hemodynamics. To determine the circumstances under which drug delivery might be delayed, or inadvertent boluses could be delivered into the manifold, two brands of commercially available clinical syringe pumps were connected to a stopcock manifold via small-bore tubing and a series of tests were performed. When the syringe pumps were operated at 3 mL/h against a closed stopcock, the pumps' occlusion alarms did not sound for 18-22 min, and when the stopcock subsequently was opened, 0.6-0.9 mL of infusate was delivered as a bolus. Elevating the syringe pump by 120 cm resulted in the delivery of up to 0.5 mL of infusate with the pump turned off. When a syringe pump operating at 6 mL/h was turned off, typically an additional 0.05 mL was delivered during the ensuing 2-3 min. Depending upon the method used to flush the tubing prior to use, delays in drug delivery of 2-3 min occurred at an infusion rate of 3 mL/h. These observations emphasize the need for careful equipment setup and proper use of the manifold stopcocks to avoid unintended drug administration or delay in drug administration.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8267151     DOI: 10.1213/00000539-199401000-00024

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  In-line filter included into the syringe infusion pump assembly reduces flow irregularities.

Authors:  B Brotschi; B Grass; M Weiss; C Doell; V Bernet
Journal:  Intensive Care Med       Date:  2012-01-12       Impact factor: 17.440

2.  Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.

Authors:  Howard C Zisser; Wendy Bevier; Eyal Dassau; Lois Jovanovic
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

3.  A Century of Technology in Anesthesia & Analgesia.

Authors:  Jane S Moon; Maxime Cannesson
Journal:  Anesth Analg       Date:  2022-07-15       Impact factor: 6.627

Review 4.  Pharmacokinetics of cardiovascular drugs in children. Inotropes and vasopressors.

Authors:  C Steinberg; D A Notterman
Journal:  Clin Pharmacokinet       Date:  1994-11       Impact factor: 6.447

5.  Efficacy evaluation of syringe pump developed for continuous drug infusion.

Authors:  Bongsu Jung; Kwang-Suk Seo; Suk Jin Kwon; Kiyoung Lee; Suyong Hong; Hyounsoon Seo; Gi-Young Kim; Geun-Mook Park; Juhee Jeong; Soowon Seo
Journal:  J Dent Anesth Pain Med       Date:  2016-12-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.