Literature DB >> 8265727

A review of the principles of pulse oximetry and accuracy of pulse oximeter estimates during exercise.

L J Mengelkoch1, D Martin, J Lawler.   

Abstract

This article reviews the principles of pulse oximetry and assesses the accuracy of pulse oximeter measurements obtained during exercise, based on reports of 10 studies that evaluated 24 pulse oximeters. Nine of the studies used cycle exercise, and 1 study utilized treadmill running for mode of activity. Subject populations included patients with cardiovascular or pulmonary disorders, nondisabled individuals, and athletes. Studies were performed under normoxic and hypoxic conditions, and 5 of the 10 studies validated 18 pulse oximeters at arterial oxyhemoglobin saturation (%HbO2) levels of < or = 78%. Sixteen of the 24 pulse oximeters (67%), from 7 of the 10 studies, observed pulse oximeter estimates (%SpO2) during exercise to be accurate, at least when %HbO2 was > or = 85% in nonsmokers. However, the degree of accuracy of the pulse oximeters was variable, even among the same models. Recent studies suggest the current generation of finger-probe-equipped pulse oximeters may be more accurate than ear-probe-equipped models. We recommend that clinicians carefully secure the probe; monitor signal strength; be wary of %SpO2 values of < or = 68% to 78% to avoid undetected severe hypoxemia; and be alert to whether a patient is a smoker, in which case %SpO2 will likely be overestimated. Researchers interested in using pulse oximeter estimates should validate their particular pulse oximeter(s) via arterial blood sampling.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8265727     DOI: 10.1093/ptj/74.1.40

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  11 in total

1.  Robust efficient estimation of heart rate pulse from video.

Authors:  Shuchang Xu; Lingyun Sun; Gustavo Kunde Rohde
Journal:  Biomed Opt Express       Date:  2014-03-10       Impact factor: 3.732

2.  The difference in respiratory and blood gas values during recovery after exercise with spontaneous versus reduced breathing frequency.

Authors:  Jernej Kapus; Anton Ušaj; Venceslav Kapus; Boro Strumbelj
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

3.  A comparison of finger and forehead pulse oximeters in heart failure patients during maximal exercise.

Authors:  Kevin L Kelly; Alex R Carlson; Thomas G Allison; Bruce D Johnson
Journal:  Heart Lung       Date:  2019-11-14       Impact factor: 2.210

4.  A field study to estimate inhalation rates for use in a particle inhalation rate exposure metric.

Authors:  Laura Corlin; Mark Woodin; Harsha Amaravadi; Noelle Henderson; Doug Brugge; John L Durant; David M Gute
Journal:  Sci Total Environ       Date:  2019-08-16       Impact factor: 7.963

5.  Unanticipated Respiratory Compromise and Unplanned Intubations on General Medical and Surgical Floors.

Authors:  Armando D Bedoya; Nrupen A Bhavsar; Bhargav Adagarla; Courtney B Page; Benjamin A Goldstein; Neil R MacIntyre
Journal:  Respir Care       Date:  2020-03-10       Impact factor: 2.339

6.  Consequences of objective self-awareness during exercise.

Authors:  Jessica E Cornick; Jim Blascovich
Journal:  Health Psychol Open       Date:  2015-08-11

7.  Reliability of Smartphone Applications for the Quantification of Oxygen Saturation.

Authors:  Almas F Khattak; Susan S Kakakhel; Noman K Wazir; Madiha Khattak; Tania Khattak; Faryal Akbar
Journal:  Cureus       Date:  2021-11-09

8.  Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.

Authors:  Pilar Martín-Escudero; Ana María Cabanas; Manuel Fuentes-Ferrer; Mercedes Galindo-Canales
Journal:  Biosensors (Basel)       Date:  2021-10-14

9.  Classification of Prefrontal Cortex Activity Based on Functional Near-Infrared Spectroscopy Data upon Olfactory Stimulation.

Authors:  Cheng-Hsuan Chen; Kuo-Kai Shyu; Cheng-Kai Lu; Chi-Wen Jao; Po-Lei Lee
Journal:  Brain Sci       Date:  2021-05-26

10.  Evaluation of a Novel Ear Pulse Oximeter: Towards Automated Oxygen Titration in Eyeglass Frames.

Authors:  Fabian Braun; Christophe Verjus; Josep Solà; Marcus Marienfeld; Manuela Funke-Chambour; Jens Krauss; Thomas Geiser; Sabina A Guler
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.