Literature DB >> 24150010

The difference in respiratory and blood gas values during recovery after exercise with spontaneous versus reduced breathing frequency.

Jernej Kapus1, Anton Ušaj, Venceslav Kapus, Boro Strumbelj.   

Abstract

Extrapolation from post-exercise measurements has been used to estimate respiratory and blood gas parameters during exercise. This may not be accurate in exercise with reduced breathing frequency (RBF), since spontaneous breathing usually follows exercise. This study was performed to ascertain whether measurement of oxygen saturation and blood gases immediately after exercise accurately reflected their values during exercise with RBF. Eight healthy male subjects performed an incremental cycling test with RBF at 10 breaths per minute. A constant load test with RBF (B10) was then performed to exhaustion at the peak power output obtained during the incremental test. Finally, the subjects repeated the constant load test with spontaneous breathing (SB) using the same protocol as B10. Pulmonary ventilation (VE), end-tidal oxygen (PETO2), and carbon dioxide pressures (PETCO2) and oxygen saturation (SaO2) were measured during both constant load tests. The partial pressures of oxygen (PO2) and carbon dioxide (PCO2) in capillary blood were measured during the last minute of exercise, immediately following exercise and during the third minute of recovery. At the end of exercise RBF resulted in lower PETO2, SaO2 and PO2, and higher PETCO2 and PCO2 when compared to spontaneous breathing during exercise. Lower SaO2 and PETO2 were detected only for the first 16s and 20s of recovery after B10 compared to the corresponding period in SB. There were no significant differences in PO2 between SB and B10 measured immediately after the exercise. During recovery from exercise, PETCO2 remained elevated for the first 120s in the B10 trial. There were also significant differences between SB and B10 in PCO2 immediately after exercise. We conclude that RBF during high intensity exercise results in hypoxia; however, due to post-exercise hyperpnoea, measurements of blood gas parameters taken 15s after cessation of exercise did not reflect the changes in PO2 and SaO2 seen during exercise. Key pointsIn some sports, the environment is inappropriate for direct measurement of respiratory and blood gas parameters during exercise. To overcome this problem, extrapolation from post-exercise measurements has often been used to estimate changes in respiratory and blood gas parameters during exercise.The possibility of hypoxia and hypercapnia during exercise with reduced breathing frequency has been tested by measuring capillary blood sampled after the exercise.Reduced breathing frequency during high intensity exercise results in hypoxia; however, due to marked post-exercise hyperventilation, measurements of blood gas parameters taken 15 s after the cessation of exercise did not yield any changes in these parameters.Despite hyperventilation during recovery, hypercapnia could be detected by measuring blood gas parameters within 15 s after the exercise with reduced breathing frequency.

Entities:  

Keywords:  Constant load test; blood gas; oxygen saturation; recovery; reduced breathing frequency; respiratory parameters

Year:  2009        PMID: 24150010      PMCID: PMC3763292     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  17 in total

1.  Arterialized capillary blood gases in exercise studies.

Authors:  J D McEvoy; N L Jones
Journal:  Med Sci Sports       Date:  1975

2.  Validity of pulse oximetry during exercise in elite endurance athletes.

Authors:  D Martin; S Powers; M Cicale; N Collop; D Huang; D Criswell
Journal:  J Appl Physiol (1985)       Date:  1992-02

3.  Blood gas measurement during exercise: a comparative study between arterialized earlobe sampling and direct arterial puncture in adults.

Authors:  I Fajac; J Texereau; V Rivoal; J F Dessanges; A T Dinh-Xuan; J Dall'Ava-Santucci
Journal:  Eur Respir J       Date:  1998-03       Impact factor: 16.671

4.  A comparison of indirect methods for continuous estimation of arterial PCO2 in men.

Authors:  P A Robbins; J Conway; D A Cunningham; S Khamnei; D J Paterson
Journal:  J Appl Physiol (1985)       Date:  1990-04

5.  Differences between estimates and measured PaCO2 during rest and exercise in older subjects.

Authors:  J S Williams; T G Babb
Journal:  J Appl Physiol (1985)       Date:  1997-07

6.  Blood lactate and metabolic responses to controlled frequency breathing during graded swimming.

Authors:  Sharon A West; Micah J Drummond; J Mark Vanness; Margaret E Ciccolella
Journal:  J Strength Cond Res       Date:  2005-11       Impact factor: 3.775

7.  Effects of reduced frequency breathing on arterial hypoxemia during exercise.

Authors:  Y Yamamoto; Y Mutoh; H Kobayashi; M Miyashita
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

8.  Metabolic consequences of reduced frequency breathing during submaximal exercise at moderate altitude.

Authors:  C Lee; L Cordain; J Sockler; A Tucker
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

9.  Ear oximetry during combined hypoxia and exercise.

Authors:  R J Smyth; A D D'Urzo; A S Slutsky; B M Galko; A S Rebuck
Journal:  J Appl Physiol (1985)       Date:  1986-02

10.  Respiratory and heart rate responses to tethered controlled frequency breathing swimming.

Authors:  S G Dicker; G K Lofthus; N W Thornton; G A Brooks
Journal:  Med Sci Sports Exerc       Date:  1980       Impact factor: 5.411

View more
  1 in total

1.  Adaptation of endurance training with a reduced breathing frequency.

Authors:  Jernej Kapus; Anton Ušaj; Mitch Lomax
Journal:  J Sports Sci Med       Date:  2013-12-01       Impact factor: 2.988

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.