Literature DB >> 8262743

Experimental hepatic tumor necrosis. Comparison of spin-echo and pulsed magnetization transfer contrast magnetic resonance imaging.

K C Li1, R B Jeffrey, S C Ning, A Kandil, G M Hahn, B Pike, G Glover, J Kosek.   

Abstract

RATIONALE AND
OBJECTIVES: We compared the effectiveness of pulsed magnetization transfer contrast (MTC) magnetic resonance imaging (MRI) and spin-echo MRI in detecting tumor necrosis.
METHODS: Adenocarcinoma cells were transplanted in the livers of 12 syngenic BDIX rats. To induce various degrees of tumor necrosis, the rats were randomly assigned to the following groups: 1) control; 2) localized hyperthermia; 3) intralesional cisplatin; and 4) hyperthermia plus intralesional cisplatin. At day 7 after treatment, the rats were imaged using a 1.5-T imager with 1) multiplanar gradient-recalled echo sequence (MPGR) 500/8/20 degrees with and without magnetization transfer contrast (MTC); 2) spin-echo 2500/20,80, and 3) spin-echo 300/20 pulse sequences. The rats were then sacrificed and pathologic specimens were prepared using MR images as guidance. T2 and ratios of signal intensity after saturation to signal intensity before saturation (Ms/Mo ratios) of the necrotic and granulation tissues and viable tumors were determined in 10 rats.
RESULTS: Compared with standard MPGR images, MPGR images with MTC provided better contrast between the pathologic tissues and normal liver. However, T2 values were more useful than Ms/Mo ratios in distinguishing necrotic areas from viable tumor. The T2 values of coagulative necrosis and granulation tissue were significantly different from that of viable tumor. No significant difference between the Ms/Mo ratios of the different pathologic tissues and normal liver was found.
CONCLUSION: Pulsed magnetization transfer contrast MRI was inferior to spin-echo MRI in distinguishing necrotic from viable tumors in rat livers using the pulse sequences described, and none of the sequences studied was thought to be reliable enough for this purpose.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8262743     DOI: 10.1097/00004424-199310000-00006

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  2 in total

1.  Improved Differentiation of Low-Grade and High-Grade Gliomas and Detection of Tumor Proliferation Using APT Contrast Fitted from Z-Spectrum.

Authors:  Jiaxuan Zhang; Wenzhen Zhu; Rongwen Tain; Xiaohong Joe Zhou; Kejia Cai
Journal:  Mol Imaging Biol       Date:  2018-08       Impact factor: 3.488

2.  Magnetization transfer contrast MRI of musculoskeletal neoplasms.

Authors:  K C Li; K L Hopkins; S G Moore; N N Loh; G Bergman; G B Pike; G H Glover
Journal:  Skeletal Radiol       Date:  1995-01       Impact factor: 2.199

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.