Literature DB >> 8260277

Comparison of acoustic quantification and Doppler echocardiography in assessment of left ventricular diastolic variables.

A Chenzbraun1, F J Pinto, S Popylisen, I Schnittger, R L Popp.   

Abstract

OBJECTIVE: To assess the haemodynamic correlations of the waveforms of left ventricular area change obtained by automated boundary detection with newly developed acoustic quantification technology.
DESIGN: The timing of events in the cardiac cycle was identified on the wave-form automated boundary detection and was correlated with the corresponding timing derived from pulsed wave Doppler flow velocity traces of the mitral valve and left ventricular outflow tract. The amounts of area change during the rapid filling phase and during atrial contraction were correlated with the time-velocity integrals of early and late diastolic ventricular filling obtained from Doppler tracings of the mitral inflow.
SETTING: A university medical school echocardiography laboratory.
SUBJECTS: 16 healthy volunteers and 19 patients referred for echocardiographic studies.
RESULTS: A significant correlation was found between the methods for measurement of the time from the R wave to mitral valve opening (r = 0.72, p < 0.01), isovolumic relaxation time (r = 0.62, p < 0.01), and ejection time (r = 0.54, p < 0.01). The change of total area that occurred during rapid filling and atrial filling phases measured from the acoustic waveform correlated with the time-velocity integrals of the early and late diastolic mitral valve inflow velocity derived from Doppler echocardiography (r = 0.60 and r = 0.80, respectively).
CONCLUSION: The waveform of left ventricular area obtained by the automated boundary detection technique identifies the phases of the cardiac cycle and correlates with Doppler values of left ventricular diastolic function. Therefore, this new method of automated boundary detection has potential uses in the assessment of left ventricular diastolic function.

Entities:  

Mesh:

Year:  1993        PMID: 8260277      PMCID: PMC1025358          DOI: 10.1136/hrt.70.5.448

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  12 in total

1.  On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging.

Authors:  J E Pérez; A D Waggoner; B Barzilai; H E Melton; J G Miller; B E Sobel
Journal:  J Am Coll Cardiol       Date:  1992-02       Impact factor: 24.094

2.  Approaches to determination of left ventricular volume and ejection fraction by real-time two-dimensional echocardiography.

Authors:  A F Parisi; P F Moynihan; C L Feldman; E D Folland
Journal:  Clin Cardiol       Date:  1979-08       Impact factor: 2.882

3.  Combined influence of ventricular loading and relaxation on the transmitral flow velocity profile in dogs measured by Doppler echocardiography.

Authors:  C Y Choong; V M Abascal; J D Thomas; J L Guerrero; S McGlew; A E Weyman
Journal:  Circulation       Date:  1988-09       Impact factor: 29.690

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles.

Authors:  H L Wyatt; S Meerbaum; M K Heng; P Gueret; E Corday
Journal:  Am Heart J       Date:  1980-12       Impact factor: 4.749

6.  Reproducibility of echocardiography. A study evaluating the variability of serial echocardiographic measurements.

Authors:  D A Pietro; A G Voelkel; B J Ray; A F Parisi
Journal:  Chest       Date:  1981-01       Impact factor: 9.410

7.  A second-generation computer-based edge detection algorithm for short-axis, two-dimensional echocardiographic images: accuracy and improvement in interobserver variability.

Authors:  E A Geiser; D A Conetta; M C Limacher; V O Stockton; L H Oliver; B Jones
Journal:  J Am Soc Echocardiogr       Date:  1990 Mar-Apr       Impact factor: 5.251

Review 8.  Doppler echocardiography for assessing left ventricular diastolic function.

Authors:  P Spirito; B J Maron
Journal:  Ann Intern Med       Date:  1988-07-15       Impact factor: 25.391

9.  Noninvasive assessment of left ventricular diastolic function: comparative analysis of Doppler echocardiographic and radionuclide angiographic techniques.

Authors:  P Spirito; B J Maron; R O Bonow
Journal:  J Am Coll Cardiol       Date:  1986-03       Impact factor: 24.094

10.  Relation of transmitral flow velocity patterns to left ventricular diastolic function: new insights from a combined hemodynamic and Doppler echocardiographic study.

Authors:  C P Appleton; L K Hatle; R L Popp
Journal:  J Am Coll Cardiol       Date:  1988-08       Impact factor: 24.094

View more
  3 in total

1.  Detection of diastolic dysfunction: acoustic quantification (AQ) in comparison to Doppler echocardiography.

Authors:  B Hausmann; S Muurling; C Stauch; A Haverich; S Hirt; R Simon
Journal:  Int J Card Imaging       Date:  1997-08

2.  Dynamic on-line quantification of biventricular function with acoustic quantification (AQ). Validation, reproducibility and normal values of a new echocardiographic approach.

Authors:  B Hausmann; S Muurling; R Simon
Journal:  Int J Card Imaging       Date:  1997-12

3.  Left atrial size and function: assessment using echocardiographic automatic boundary detection.

Authors:  P B Clarkson; N M Wheeldon; P O Lim; S D Pringle; T M MacDonald
Journal:  Br Heart J       Date:  1995-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.