Literature DB >> 8258548

Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.

D H Silcox1, M D Rooks, R R Vogel, L L Fleming.   

Abstract

Forty-four patients who had had a total of forty-seven amputations of an upper extremity and who had had a myoelectric prosthesis for more than two years were evaluated retrospectively for the amount of use of the prosthesis, the use of any other prosthesis, and the demographic factors that might be related to use of the prosthesis. The average duration of follow-up was five years (range, twenty-five months to seventeen years). Forty of the forty-four patients also had a conventional prosthesis. Twenty-two patients (50 per cent) rejected the myoelectric prosthesis completely; thirteen (32 per cent) of the forty patients who also had a conventional prosthesis rejected the conventional prosthesis completely. The patients who used the myoelectric device the least were employed in occupations that required high-demand use of the prosthesis (lifting of more than 4.5 kilograms [ten pounds] or repetitive manual labor) or were receiving or seeking Workers' Compensation, or both.

Entities:  

Mesh:

Year:  1993        PMID: 8258548     DOI: 10.2106/00004623-199312000-00007

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  15 in total

Review 1.  ["Bionic" arm prostheses. State of the art in research and development].

Authors:  C Pylatiuk; L Döderlein
Journal:  Orthopade       Date:  2006-11       Impact factor: 1.087

2.  Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system.

Authors:  Christian Antfolk; Christian Balkenius; Göran Lundborg; Birgitta Rosén; Fredrik Sebelius
Journal:  Biomed Eng Online       Date:  2010-09-14       Impact factor: 2.819

3.  A Multigrasp Hand Prosthesis for Providing Precision and Conformal Grasps.

Authors:  Daniel A Bennett; Skyler A Dalley; Don Truex; Michael Goldfarb
Journal:  IEEE ASME Trans Mechatron       Date:  2014-09-11       Impact factor: 5.303

4.  Evaluation of head orientation and neck muscle EMG signals as command inputs to a human-computer interface for individuals with high tetraplegia.

Authors:  Matthew R Williams; Robert F Kirsch
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-10       Impact factor: 3.802

5.  Design of a cybernetic hand for perception and action.

Authors:  M C Carrozza; G Cappiello; S Micera; B B Edin; L Beccai; C Cipriani
Journal:  Biol Cybern       Date:  2006-12-06       Impact factor: 2.086

6.  Myoelectric hand prostheses in very young children.

Authors:  Marcus Egermann; Philip Kasten; Marc Thomsen
Journal:  Int Orthop       Date:  2008-07-18       Impact factor: 3.075

7.  Opinions of youngsters with congenital below-elbow deficiency, and those of their parents and professionals concerning prosthetic use and rehabilitation treatment.

Authors:  Ecaterina Vasluian; Ingrid G M de Jong; Wim G M Janssen; Margriet J Poelma; Iris van Wijk; Heleen A Reinders-Messelink; Corry K van der Sluis
Journal:  PLoS One       Date:  2013-06-24       Impact factor: 3.240

8.  The development of a myoelectric training tool for above-elbow amputees.

Authors:  Michael R Dawson; Farbod Fahimi; Jason P Carey
Journal:  Open Biomed Eng J       Date:  2012-02-20

9.  Evaluation of head orientation and neck muscle EMG signals as three-dimensional command sources.

Authors:  Matthew R Williams; Robert F Kirsch
Journal:  J Neuroeng Rehabil       Date:  2015-03-05       Impact factor: 4.262

10.  SoftHand at the CYBATHLON: a user's experience.

Authors:  Sasha Blue Godfrey; Matteo Rossi; Cristina Piazza; Manuel Giuseppe Catalano; Matteo Bianchi; Giorgio Grioli; Kristin D Zhao; Antonio Bicchi
Journal:  J Neuroeng Rehabil       Date:  2017-11-29       Impact factor: 4.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.