D-dimer in patients with clinically suspected pulmonary embolism.

J S Ginsberg1, P A Brill-Edwards, C Demers, D Donovan, A Panju.   

Abstract

STUDY
OBJECTIVE: To determine whether measurement of D-dimer, using an enzyme-linked immunosorbent assay (ELISA) with a cutoff of 300 ng/ml, and a latex agglutination assay with a cutoff of 500 ng/ml, is clinically useful in patients with suspected pulmonary embolism (PE).
DESIGN: Prospective cohort.
SETTING: Tertiary care referral center, university-affiliated hospital. PATIENTS: Two hundred twenty-one consecutive patients with clinically suspected PE. INTERVENTION: All patients had blood drawn to measure levels of D-dimer and underwent ventilation/perfusion (V/Q) lung scanning and bilateral impedance plethysmography (IPG); pulmonary angiography was performed in nine patients. Patients were classified as follows: (1) PE-positive; positive pulmonary angiography or high probability V/Q scan or non-high-probability V/Q scan and either abnormal IPG (either at presentation or on serial testing and confirmed by contrast venography) or symptomatic thromboembolic event within 3 months of presentation; or (2) PE-negative; normal V/Q scan or normal pulmonary angiography or non-high-probability V/Q scan and either normal serial IPG or abnormal IPG with normal venography and absence of symptomatic venous thromboembolism within 3 months of followup. Forty-three patients were classified as PE positive and 178 patients were classified as PE negative. MEASUREMENTS AND
RESULTS: The sensitivities, specificities, positive predictive values, and negative predictive values of the ELISA and latex agglutination assay were calculated for all patients and for the subgroup of patients with non-high-probability V/Q scans. The ELISA D-dimer, using a cutoff of 300 ng/ml, showed a sensitivity and negative predictive value of 100 percent in all patients and patients with non-high-probability V/Q scans, but the corresponding specificities were only 26 percent and 13 percent, respectively. The latex agglutination assay for D-dimer using a cutoff of 500 ng/ml showed the following: sensitivities of 84 percent in all patients and 90 percent in patients with non-high-probability scans, negative predictive values of 93 percent in all patients, and 98 percent in patients with non-high-probability scans and specificities of 56 percent in all patients and 55 percent in patients with non-high-probability scans.
CONCLUSIONS: This study demonstrates that an ELISA D-dimer result of less than 300 ng/ml excludes PE but occurs in a small proportion of patients with clinically suspected PE. The latex agglutination assay, using a cutoff of 500 ng/ml, has potential clinical utility in excluding PE in the subgroup of patients with clinically suspected PE and non-high-probability V/Q scans. However, the 95 percent confidence interval on the observed sensitivity of the latex agglutination assay in patients with non-high-probability V/Q scans is wide. Therefore, these promising results should be confirmed in a large clinical trial before the latex agglutination assay is used to make management decisions.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8252941     DOI: 10.1378/chest.104.6.1679

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

1.  Predictive Value of the Rapid Whole Blood Agglutination D-Dimer Assay (AGEN SimpliRED) in Community Outpatients with Suspected Deep Venous Thrombosis.

Authors:  Julieta E Hayag; Prem P Manchanda
Journal:  Perm J       Date:  2006

2.  Screening for pulmonary embolism with a D-dimer assay: do we still need to assess clinical probability as well?

Authors:  Christopher J Hammond; Tajek B Hassan
Journal:  J R Soc Med       Date:  2005-02       Impact factor: 18.000

3.  Visual inspection for diagnosing cutaneous melanoma in adults.

Authors:  Jacqueline Dinnes; Jonathan J Deeks; Matthew J Grainge; Naomi Chuchu; Lavinia Ferrante di Ruffano; Rubeta N Matin; David R Thomson; Kai Yuen Wong; Roger Benjamin Aldridge; Rachel Abbott; Monica Fawzy; Susan E Bayliss; Yemisi Takwoingi; Clare Davenport; Kathie Godfrey; Fiona M Walter; Hywel C Williams
Journal:  Cochrane Database Syst Rev       Date:  2018-12-04

4.  Monoclonal antibodies with equal specificity to D-dimer and high-molecular-weight fibrin degradation products.

Authors:  Alexander E Kogan; Kadriya S Mukharyamova; Anastasia V Bereznikova; Vladimir L Filatov; Ekaterina V Koshkina; Marina N Bloshchitsyna; Alexey G Katrukha
Journal:  Blood Coagul Fibrinolysis       Date:  2016-07       Impact factor: 1.276

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.