Literature DB >> 8246299

Structure of the bone interface to dental implants in vivo.

G De Lange1, C De Putter.   

Abstract

Dental implant materials can develop different kinds of interfaces when used for bone or tooth substitution. This paper describes the tissues and the tissue reactions of the interface created in the implantation bed between bone tissue and implants made of dense sintered hydroxylapatite. Healing was clinically and histologically evaluated during a six-month to five-year period. The light microscopic results show extensive bone apposition on the osseous sides of loaded implant cylinders and also on subperiosteally placed granules of dense hydroxylapatite. The presence of the loaded implant did not disturb the normal bone physiology. Bone turnover also included the bone tissue toward the implant surface. At the ultrastructural level, an amorphous collagen-free zone of about 200 nm was frequently observed which was separated from the surrounding mineralized extracellular matrix by a thin, electron-dense layer of about 20-100 A. Contact microradiographs showed an intimate bond to bone. The bone growth extending up the implant cylinder was always accompanied with an embedding of collagen fibers and the presence of a well-developed and complete new gingival attachment apparatus. This was confirmed by scanning electron microscopy. However, any inflammatory reactions in the transmucosal area were accompanied with concomitant bone resorption and loss of bone support.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8246299

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Synthesis of nano-sized biphasic calcium phosphate ceramics with spherical shape by flame spray pyrolysis.

Authors:  Jung Sang Cho; You Na Ko; Hye Young Koo; Yun Chan Kang
Journal:  J Mater Sci Mater Med       Date:  2010-01-06       Impact factor: 3.896

2.  Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients.

Authors:  Fras Dakhil-Jerew; H Jadeja; A Cohen; J A N Shepperd
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

3.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.