Literature DB >> 8245580

Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometry.

A A De Leeuw1, J Crezee, J J Lagendijk.   

Abstract

Multisensor (7-14) thermocouple thermometry is used at our department for temperature measurement with our 'Coaxial TEM' regional hyperthermia system. A special design of the thermometry system with high resolution (0.005 degrees C) and fast data-acquisition (all channels within 320 ms) together with a pulsed power technique allows assessment of specific absorption rate (SAR) information in patients along catheter tracks. A disadvantage of thermocouple thermometry, EM interference, is almost entirely eliminated by application of absorbing ferrite beads around the probe leads. We investigated the effect of remaining disturbance on the temperature decay after power-off, both experimentally in phantoms and in the clinic, and with numerical simulations. Probe and tissue characteristics influence the response time tau dist of the decay of the disturbance. In our clinical practice a normal pulse sequence is 50 s power-on, 10 s power-off: a response time longer than the power-off time results in a deflection of the temperature course at the start. Based on analysis of temperature decays correction of temperature is possible. A double-pulse technique is introduced to provide an initial correction of temperature, and fast information about accuracy. Sometimes disturbance with a relatively long response time occurs, probably due to a bad contact between probe, catheter and/or tissue. Thermocouple thermometry proved to be suitable to measure the SAR along a catheter track. This is used to optimize the SAR distribution by patient positioning before treatment. A clinical example illustrates this.

Entities:  

Mesh:

Year:  1993        PMID: 8245580     DOI: 10.3109/02656739309032056

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  8 in total

1.  Quality assurance for clinical studies in regional deep hyperthermia.

Authors:  Gregor Bruggmoser; Stefan Bauchowitz; Richard Canters; Hans Crezee; Michael Ehmann; Johanna Gellermann; Ulf Lamprecht; Nicoletta Lomax; Marc Benjamin Messmer; Oliver Ott; Sultan Abdel-Rahman; Rolf Sauer; Manfred Schmidt; Andreas Thomsen; Rüdiger Wessalowski; Gerard van Rhoon
Journal:  Strahlenther Onkol       Date:  2011-09-19       Impact factor: 3.621

2.  Guideline for the clinical application, documentation and analysis of clinical studies for regional deep hyperthermia: quality management in regional deep hyperthermia.

Authors:  G Bruggmoser; S Bauchowitz; R Canters; H Crezee; M Ehmann; J Gellermann; U Lamprecht; N Lomax; M B Messmer; O Ott; S Abdel-Rahman; M Schmidt; R Sauer; A Thomsen; R Wessalowski; G van Rhoon
Journal:  Strahlenther Onkol       Date:  2012-09       Impact factor: 3.621

Review 3.  Gesture as representational action: A paper about function.

Authors:  Miriam A Novack; Susan Goldin-Meadow
Journal:  Psychon Bull Rev       Date:  2017-06

Review 4.  Heating technology for malignant tumors: a review.

Authors:  H Petra Kok; Erik N K Cressman; Wim Ceelen; Christopher L Brace; Robert Ivkov; Holger Grüll; Gail Ter Haar; Peter Wust; Johannes Crezee
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

5.  A short time interval between radiotherapy and hyperthermia reduces in-field recurrence and mortality in women with advanced cervical cancer.

Authors:  Caspar M van Leeuwen; Arlene L Oei; Kenneth W T K Chin; Johannes Crezee; Arjan Bel; Anneke M Westermann; Marrije R Buist; Nicolaas A P Franken; Lukas J A Stalpers; H Petra Kok
Journal:  Radiat Oncol       Date:  2017-04-27       Impact factor: 3.481

6.  Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients.

Authors:  Akke Bakker; Remko Zweije; Henny Petra Kok; Merel Willemijn Kolff; H J G Desiree van den Bongard; Manfred Schmidt; Geertjan van Tienhoven; Hans Crezee
Journal:  Cancers (Basel)       Date:  2020-12-04       Impact factor: 6.639

Review 7.  Avoiding Pitfalls in Thermal Dose Effect Relationship Studies: A Review and Guide Forward.

Authors:  Carolina Carrapiço-Seabra; Sergio Curto; Martine Franckena; Gerard C Van Rhoon
Journal:  Cancers (Basel)       Date:  2022-09-30       Impact factor: 6.575

Review 8.  Temperature Sensing Performance of Microsphere Resonators.

Authors:  Jibo Yu; Elfed Lewis; Gilberto Brambilla; Pengfei Wang
Journal:  Sensors (Basel)       Date:  2018-08-01       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.