Selective control of muscle activation with a multipolar nerve cuff electrode.

C Veraart1, W M Grill, J T Mortimer.   

Abstract

Acute experiments were performed on adult cats to study selective activation of medial gastrocnemius, soleus, tibialis anterior, and extensor digitorum longus with a cuff electrode. A spiral nerve cuff containing twelve "dot" electrodes was implanted around the sciatic nerve and evoked muscle twitch forces were recorded in six experiments. Spatially isolated "dot" electrodes in four geometries: monopolar, longitudinal tripolar, tripolar with four common anodes, and two parallel tripoles, were combined with transverse field steering current(s) from an anode(s) located 180 degrees around from the cathode(s) to activate different regions of the nerve trunk. To quantify the degree of selectivity, a selectivity index was defined as the ratio of the force in one muscle to the force in all four muscles in response to a particular stimulus. The selectivity index was used to construct recruitment curves for a muscle with the optimal degree of selectivity. Physiological responses were correlated with the anatomical structure of the sciatic nerve by identifying the nerve fascicles innervating the four muscles, and by determining the relative positions of the electrodes and the nerve fascicles. The results indicated that the use of transverse field steering current improved selectivity. We also found that tripoles with individual dot anodes were more selective than tripoles with four common dot anodes. Stimulation with two parallel tripoles was effective in activating selectively fascicles that could not be activated selectively with only a single tripole. The multipolar cuff proved an effective method to control selectively and progressively the force in muscles innervated by fascicles that were well defined at the level of the cuff.

Entities:  

Mesh:

Year:  1993        PMID: 8244425     DOI: 10.1109/10.237694

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  40 in total

1.  Hybrid finite elements and spectral method for computation of the electric potential generated by a nerve cuff electrode.

Authors:  S Parrini; J Delbeke; E Romero; V Legat; C Veraart
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Neural morphological effects of long-term implantation of the self-sizing spiral cuff nerve electrode.

Authors:  E Romero; J F Denef; J Delbeke; A Robert; C Veraart
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

3.  Force-current relationships in intraneural stimulation: role of extraneural medium and motor fibre clustering.

Authors:  T A Frieswijk; J P Smit; W L Rutten; H B Boom
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

4.  Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use.

Authors:  Emily L Foldes; D Michael Ackermann; Niloy Bhadra; Kevin L Kilgore; Narendra Bhadra
Journal:  J Neurosci Methods       Date:  2010-12-25       Impact factor: 2.390

5.  Two-way communication for programming and measurement in a miniature implantable stimulator.

Authors:  M A Thil; B Gérard; J C Jarvis; J Delbeke
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

6.  Current steering to control the volume of tissue activated during deep brain stimulation.

Authors:  Christopher R Butson; Cameron C McIntyre
Journal:  Brain Stimul       Date:  2008-01       Impact factor: 8.955

7.  Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity.

Authors:  K E Deurloo; J Holsheimer; H B Boom
Journal:  Med Biol Eng Comput       Date:  1998-01       Impact factor: 2.602

8.  Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity.

Authors:  Katharine H Polasek; Harry A Hoyen; Michael W Keith; Robert F Kirsch; Dustin J Tyler
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-09-22       Impact factor: 3.802

9.  Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve.

Authors:  L E Fisher; D J Tyler; J S Anderson; R J Triolo
Journal:  J Neural Eng       Date:  2009-07-15       Impact factor: 5.379

10.  A nerve cuff electrode for controlled reshaping of nerve geometry.

Authors:  Anthony V Caparso; Dominique M Durand; Joseph M Mansour
Journal:  J Biomater Appl       Date:  2008-11-05       Impact factor: 2.646