Literature DB >> 8235874

Complications of the Wiltse Pedicle Screw Fixation System.

S Blumenthal1, K Gill.   

Abstract

The purpose of the current study is to retrospectively review the incidence and types of complications occurring using a single pedicle screw fixation system for lumbar spine fusions. For a 3-year period beginning in July 1987, 470 patients underwent spinal fusion and instrumentation with the Wiltse Pedicle Screw Fixation System. Although multiple configurations of the Wiltse System were included, the predominant construct was that of segmental pedicle screw fixation. Complications occurred in a total of 29 patients, for an overall complication rate of 6%. Among the complications were 10 wound problems (2%) that included 2 seromas requiring drainage and 3 superficial wound infections. The remaining five wound complications were deep wound infections requiring irrigation and debridement. The overall deep wound infection rate was 1%. Neurologic complications occurred in two patients, one with temporary foot drop and one with persistent L5 nerve root irritation confirmed by electromyogram (EMG). Both of these patients underwent anatomic workup, which failed to reveal any evidence of impingement by either screw or other hard tissue. Two intraoperative complications occurred, both involving fracture of the L5 pedicle. No adverse sequela resulted. There were 15 hardware complications, for an overall rate of 3%. This included four patients with broken screws (a total of eight screws). There were three failures at the screw-bone interface, as well as four patients with uncoupling of the screw rod linkage. In addition, there were four broken rods encountered. A total of 122 Wiltse devices were removed, for an overall removal rate of 25%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8235874     DOI: 10.1097/00007632-199310000-00024

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  11 in total

1.  Measurements of the lumbar pedicles in the Eastern Anatolian population.

Authors:  H H Kadioglu; E Takci; A Levent; M Arik; I H Aydin
Journal:  Surg Radiol Anat       Date:  2003-05-14       Impact factor: 1.246

2.  Mechanical implant failure in posterior cervical spine fusion.

Authors:  Takeshi Okamoto; Masashi Neo; Shunsuke Fujibayashi; Hiromu Ito; Mitsuru Takemoto; Takashi Nakamura
Journal:  Eur Spine J       Date:  2011-10-16       Impact factor: 3.134

3.  Early complications of spinal pedicle screw.

Authors:  A A Faraj; J K Webb
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Design methodology for a simulator of a robotic surgical system.

Authors:  Danielle L Julian; Roger D Smith; Alyssa D S Tanaka; Ariel Dubin
Journal:  J Robot Surg       Date:  2018-11-30

5.  In vitro testing of a new transpedicular stabilization technique.

Authors:  M Pfeiffer; H Hoffman; V K Goel; J N Weinstein; P Griss
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

6.  Computer analysis of the safety of using three different pedicular screw insertion points in the lumbar spine in the Chinese population.

Authors:  Yu Hailong; Lei Wei; Ma Zhensheng; Sang Hongxun
Journal:  Eur Spine J       Date:  2006-10-13       Impact factor: 3.134

Review 7.  Pelvic fixation for adult scoliosis.

Authors:  Francis H Shen; Jonathan R Mason; Adam L Shimer; Vincent M Arlet
Journal:  Eur Spine J       Date:  2012-10-23       Impact factor: 3.134

8.  Clinical efficacy of pedicle instrumentation and posterolateral fusion in the symptomatic degenerative lumbar spine.

Authors:  J D Rompe; P Eysel; C Hopf
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

9.  Mid-range outcomes in 64 consecutive cases of multilevel fusion for degenerative diseases of the lumbar spine.

Authors:  Marc Röllinghoff; Klaus Schlüter-Brust; Daniel Groos; Rolf Sobottke; Joern William-Patrick Michael; Peer Eysel; Karl Stefan Delank
Journal:  Orthop Rev (Pavia)       Date:  2010-03-20

10.  Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories.

Authors:  Peter A J Pijpker; Joep Kraeima; Max J H Witjes; D L Marinus Oterdoom; Rob A Vergeer; Maarten H Coppes; Rob J M Groen; Jos M A Kuijlen
Journal:  Spine (Phila Pa 1976)       Date:  2021-02-01       Impact factor: 3.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.