Literature DB >> 8234646

Effect of luting media on the compressive strengths of two types of all-ceramic crown.

J T McCormick1, W Rowland, H T Shillingburg, M G Duncanson.   

Abstract

This study evaluated the effect of selected luting media on the compressive strength of two types of all-ceramic crown. Tooth preparation was standardized; each preparation had a shoulder width of approximately 1.2 mm, and all internal preparation angles were rounded. Hi-Ceram and Dicor all-ceramic crowns were fabricated and cemented into the preparations with zinc phosphate, glass-ionomer, or composite resin cement. Coronal compressive fracture strengths were determined, using a set of unrestored teeth as a control. There were no statistically significant differences among the mean compressive strengths of the three luting media, and there was no statistically significant difference between the mean compressive strength of Dicor and that of the natural tooth control.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8234646

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  7 in total

Review 1.  All-ceramic crowns: bonding or cementing?

Authors:  Peter Pospiech
Journal:  Clin Oral Investig       Date:  2002-11-21       Impact factor: 3.573

2.  Evaluation of adhesive bonding of lithium disilicate ceramic material with duel cured resin luting agents.

Authors:  Dipti Pravin Lambade; Sham M Gundawar; Usha M Radke
Journal:  J Clin Diagn Res       Date:  2015-02-01

3.  Comparison of the wet and dry fatigue properties of all ceramic crowns.

Authors:  L C Sobrinho; R H Glover; J C Knowles; M J Cattell
Journal:  J Mater Sci Mater Med       Date:  1998-09       Impact factor: 3.896

4.  Fracture strength of all-ceramic crowns.

Authors:  L C Sobrinho; M J Cattell; J C Knowles
Journal:  J Mater Sci Mater Med       Date:  1998-10       Impact factor: 3.896

5.  Use of zinc phosphate cement as a luting agent for Denzir trade mark copings: an in vitro study.

Authors:  Karl-Johan M Söderholm; Eduardo Mondragon; Ileana Garcea
Journal:  BMC Oral Health       Date:  2003-02-07       Impact factor: 2.757

Review 6.  Cementation of Glass-Ceramic Posterior Restorations: A Systematic Review.

Authors:  Carline R G van den Breemer; Marco M M Gresnigt; Marco S Cune
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

7.  Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crowns.

Authors:  Fahim Vohra; Manea Altwaim; Abdulaziz S Alshuwaier; Modhi Al Deeb; Yasser Alfawaz; Mohammed Alrabiah; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2020 Mar-Apr       Impact factor: 1.088

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.