Literature DB >> 8231317

Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG.

O J Escalona1, R H Mitchell, D E Balderson, D W Harron.   

Abstract

The process of QRS alignment as required in signal-averaged ECG can impose serious limitations on the spectral range of the signal output. This effect depends basically on the particular alignment technique being used and on the level and type of noise present in the recorded ECG. In clinical studies where a wide-band (1000 Hz) ECG averager is required, the conventional QRS alignment technique, based on maximum coherence matching (MCM) with a template beat, may not perform consistently well. An alternative QRS alignment technique based on the accurate detection of a single fiducial point (SFP) in the bandpass filtered (3-30 Hz) QRS complex was developed. Using computer simulation methods, a comparative assessment of the frequency bandwidths (3 dB points) offered by both MCM and SFP techniques as a function of noise level (15-100 muRMS) and type (EMG and 50 Hz interference), was carried out. The results of the comparative assessment indicated a better performance by the SFP technique in all cases of noise. Hence, the SFP technique would perform more reliably for high-frequency analysis of a noisy ECG, especially when 50 Hz interference is high. Furthermore, SFP is considerably faster than MCM (about four times) when implemented digitally, and its analogue realisation is feasible. The SFP technique is suitable for late-potential analysis in the signal-averaged ECG.

Mesh:

Year:  1993        PMID: 8231317     DOI: 10.1007/bf02446662

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  17 in total

1.  Methods for non-invasive detection of ventricular late potentials--a comparative multicenter study.

Authors:  M Oeff; E R von Leitner; R Sthapit; G Breithardt; M Borggrefe; U Karbenn; T Meinertz; R Zotz; W Clas; V Hombach
Journal:  Eur Heart J       Date:  1986-01       Impact factor: 29.983

2.  Diverse characteristics in potential waveform of His-Purkinje system--experimental and simulation studies.

Authors:  J Toyama; C Satoh; T Watanabe; I Kodama; K Yamada
Journal:  Jpn Circ J       Date:  1988-02

3.  Importance of the endpoint of noise reduction in analysis of the signal-averaged electrocardiogram.

Authors:  J S Steinberg; J T Bigger
Journal:  Am J Cardiol       Date:  1989-03-01       Impact factor: 2.778

4.  Performance degradation of the coherent averaging technique by a molding effect.

Authors:  F Lippens; P Savard; M Shenasa
Journal:  IEEE Trans Biomed Eng       Date:  1989-08       Impact factor: 4.538

5.  Clinical significance of high frequency QRS potentials in myocardial infarction: analysis based on power spectrum of lead III.

Authors:  K K Talwar; G S Rao; U Nayar; M L Bhatia
Journal:  Cardiovasc Res       Date:  1989-01       Impact factor: 10.787

6.  High frequency electrocardiography using an advanced method of signal averaging for non-invasive detection of coronary artery disease in patients with normal conventional electrocardiogram.

Authors:  S Abboud; B Belhassen; H I Miller; D Sadeh; S Laniado
Journal:  J Electrocardiol       Date:  1986-10       Impact factor: 1.438

7.  Signal-averaged electrocardiography in the time and frequency domains.

Authors:  T A Buckingham; C M Thessen; D Hertweck; D L Janosik; H L Kennedy
Journal:  Am J Cardiol       Date:  1989-04-01       Impact factor: 2.778

8.  Role of bandpass filters in optimizing the value of the signal-averaged electrocardiogram as a predictor of the results of programmed stimulation.

Authors:  E B Caref; G Turitto; B B Ibrahim; R Henkin; N el-Sherif
Journal:  Am J Cardiol       Date:  1989-07-01       Impact factor: 2.778

9.  Differentiation between late potentials of right ventricular and of left ventricular origin.

Authors:  T Ohe; A Konoe; A Shimizu; S Daikoku; S Kamakura; M Matsuhisa; N Aihara; I Sato; K Shimomura
Journal:  Am J Cardiol       Date:  1989-07-01       Impact factor: 2.778

10.  Effect of myocardial infarction on high-frequency QRS potentials.

Authors:  A L Goldberger; V Bhargava; V Froelicher; J Covell
Journal:  Circulation       Date:  1981-07       Impact factor: 29.690

View more
  1 in total

1.  Armband Sensors Location Assessment for Left Arm-ECG Bipolar Leads Waveform Components Discovery Tendencies around the MUAC Line.

Authors:  Omar Escalona; Sephorah Mukhtar; David McEneaney; Dewar Finlay
Journal:  Sensors (Basel)       Date:  2022-09-24       Impact factor: 3.847