Literature DB >> 8231145

Laser anemometry measurements of steady flow past aortic valve prostheses.

Y T Chew1, H T Low, C N Lee, S S Kwa.   

Abstract

An experimental investigation was conducted in steady flow to examine the fluid dynamics performance of three prosthetic heart valves of 27 mm diameter: Starr-Edwards caged ball valve, Bjork-Shiley convexo-concave tilting disk valve, and St. Vincent tilting disk valve. It was found that the pressure loss across the St. Vincent valve is the least and is, in general, about 70 percent of that of the Starr-Edwards valve. The pressure recovery is completed about 4 diameters downstream. The velocity profiles for the ball valve reveal a large single reversed flow region behind the occluder while those for the tilting disks valves reveal two reversed flow regions immediately behind the occluders. Small regions of stasis are also found near the wall in the minor opening of Bjork-Shiley valve and in the major opening of St. Vincent valve. The maximum wall shear stresses of the three valves at a flow rate of 30 l/min are in the range 30-50 dyn/cm2 which can cause hemolysis of attached red blood cells. The corresponding maximum Reynolds normal stresses are in the range of 1600-3100 dyn/cm2. The Reynolds normal stresses decay quickly and return approximately to the upstream undisturbed level at about 4 diameters downstream while the wall shear stresses decay at a slower rate. The maximum Reynolds normal stresses occur at about 1 diameter downstream while the maximum wall shear stress is at about 2 diameters downstream. In general, the St. Vincent valve has better performance.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8231145     DOI: 10.1115/1.2895489

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

Authors:  Yubing Shi; Tony Joon Hock Yeo; Yong Zhao; Ned H C Hwang
Journal:  J Biol Phys       Date:  2007-03-28       Impact factor: 1.365

Review 2.  A relationship between Reynolds stresses and viscous dissipation: implications to red cell damage.

Authors:  S A Jones
Journal:  Ann Biomed Eng       Date:  1995 Jan-Feb       Impact factor: 3.934

3.  Particle image velocimetry in the investigation of flow past artificial heart valves.

Authors:  W L Lim; Y T Chew; T C Chew; H T Low
Journal:  Ann Biomed Eng       Date:  1994 May-Jun       Impact factor: 3.934

  3 in total