Literature DB >> 8230346

Cortical bone reactions at the interface of external fixation half-pins under different loading conditions.

H T Aro1, M D Markel, E Y Chao.   

Abstract

The pin-bone interface is the weakest link in the mechanical stability of external skeletal fixation. In this investigation, a canine model was used to characterize the nature of cortical bone reactions at the pin-bone interface. Unilateral external fixators were applied to the tibiae of 61 dogs using six tapered cortical half-pins. The pins were inserted after predrilling both cortices, and pin insertion torque was measured. A transverse or oblique osteotomy was performed in each tibia and stabilized under different gap conditions. Unrestricted weight bearing was allowed immediately after surgery. Sequential functional evaluations of the animals and biweekly roentgenograms of the pin tracks were done. Pin removal torques were recorded at the time the animals were killed at different time periods. Pin tracks were analyzed using quantitative tetracycline histomorphometry and microradiography. The results showed that cortical bone undergoes extensive creeping substitution around external fixation half-pins. New bone accounted for approximately 43% of the intracortical space along the pin track, and cortical bone porosity showed a fourfold increase compared with intact bone value. This cortical bone remodeling resulted in a time-related decrease of pin removal torque (p < 0.001). In inherently unstable oblique osteotomies, and less in stable rigidly fixed transverse osteotomies, immediate postoperative weight bearing caused bone thread resorption and adverse cortical bone remodeling at the entry cortex of external fixation half-pins. The unicortical loosening of half-pins that became evident during the first month of fixation obviously represents a consequence of micromotion and local bone yielding failure caused by high dynamic stresses of the pin-bone interface. Effective precautions should be taken to reduce such stresses.

Entities:  

Mesh:

Year:  1993        PMID: 8230346     DOI: 10.1097/00005373-199311000-00022

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  13 in total

1.  Comparison of a reverse-transverse cross pin technique with a same side cross pin type II external skeletal fixator in 89 dogs.

Authors:  Kun-Yang Tsai; Matthew Pead
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

3.  Efficacy of fentanyl and/or lidocaine on total antioxidants and total oxidants during craniotomy.

Authors:  Ayse Mizrak; Ibrahim Erkutlu; Mehmet Alptekin; Elzem Sen; Murat Geyik; Abdulvahab Gok; Unsal Oner
Journal:  Clin Med Res       Date:  2011-01-24

4.  Outcome evaluation of new calcium titanate schanz-screws for external fixators. First clinical results and cadaver studies.

Authors:  Martin Gathen; Milena Maria Ploeger; Max Jaenisch; Sebastian Koob; Davide Cucchi; Adnan Kasapovic; Thomas Randau; Richard Placzek
Journal:  J Mater Sci Mater Med       Date:  2019-11-08       Impact factor: 3.896

5.  Short- and long-term success of transfixation pin casts used to stabilize long bone fractures in ruminants.

Authors:  Joseph W Lozier; Andrew J Niehaus; Andrew Muir; Jeffrey Lakritz
Journal:  Can Vet J       Date:  2018-06       Impact factor: 1.008

6.  Drug loading and release of Tobramycin from hydroxyapatite coated fixation pins.

Authors:  Mirjam Lilja; Jan Henrik Sörensen; Ulrika Brohede; Maria Astrand; Philip Procter; Jörg Arnoldi; Hartwig Steckel; Maria Strømme
Journal:  J Mater Sci Mater Med       Date:  2013-06-19       Impact factor: 3.896

7.  Stability with unilateral external fixation in the tibia.

Authors:  N Giotakis; B Narayan
Journal:  Strategies Trauma Limb Reconstr       Date:  2007-04

8.  Stability at the half pin-frame interface on external fixation constructs.

Authors:  Alexios Dimitrios Iliadis; Parag Kumar Jaiswal; Jay Meswania; Gordon Blunn; David Goodier; Peter Calder
Journal:  Strategies Trauma Limb Reconstr       Date:  2016-10-13

9.  Initial clinical trial of pins coated with fibroblast growth factor-2-apatite composite layer in external fixation of distal radius fractures.

Authors:  Yohei Yanagisawa; Atsuo Ito; Yuki Hara; Hirotaka Mutsuzaki; Shinji Murai; Kengo Fujii; Yu Sogo; Motohiro Hirose; Ayako Oyane; Fumiko Kobayashi; Masashi Yamazaki
Journal:  J Orthop       Date:  2018-12-20

10.  Clinical and histomorphometrical study on titanium dioxide-coated external fixation pins.

Authors:  Hironobu Koseki; Tomohiko Asahara; Takayuki Shida; Itaru Yoda; Hidehiko Horiuchi; Koumei Baba; Makoto Osaki
Journal:  Int J Nanomedicine       Date:  2013-02-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.