Literature DB >> 8228721

Automated measurement of QT interval dispersion from hard-copy ECGs.

H K Bhullar1, J C Fothergill, W P Goddard, D P de Bono.   

Abstract

Increased "dispersion" of the QT interval of the electrocardiogram has been proposed as a marker for increased risk of cardiac arrhythmias, but definitive identification of its independent predictive value requires accurate and reproducible measurement in large numbers of cases. A personal computer-based technique for (1) converting hard-copy electrocardiograms to digital records and (2) automatically measuring QT interval dispersion from the digitized records has been developed and validated. Hand measurements of the RR interval from the original tracing and cursor or automated measurements from digitized waveforms correlated to within 1%. QT intervals measured by cursor on digitized waveforms were a mean of 14 ms (95% confidence interval, 10-19 ms) longer than manual measurements on original tracings. Automatic QT interval measurements were a mean of 5 ms longer than cursor measurements (95% confidence interval, 3-7 ms). Automated measurements were observer independent and repeatable (coefficient of variation for repeat measurements, 0.137% RR and 0.370% QT). Estimates of QT dispersion (expressed as coefficient of interlead QT variation) were made for 14 patients with documented recurrent ventricular and 15 control subjects. The median coefficient of interlead QT variation was 8.8% (range, 4.4-12.4%) for arrhythmia patients and 3.6% (range, 2.7-6.3%) for the control group (P < .001). The automatic measurements were more conservative and less likely to give spuriously large values for QT dispersion than manual measurements. Automated QT dispersion measurements should facilitate future studies on predicting the risk of ventricular arrhythmias.

Entities:  

Mesh:

Year:  1993        PMID: 8228721     DOI: 10.1016/0022-0736(93)90053-g

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  6 in total

1.  Measurement error as a source of QT dispersion: a computerised analysis.

Authors:  J A Kors; G van Herpen
Journal:  Heart       Date:  1998-11       Impact factor: 5.994

2.  Earliest time of change in QT dispersion after stenting in patients with single vessel coronary artery disease.

Authors:  Gholam Reza Rezaian; Hooman Shariati Ghadicolay; Mohammad Bagher Sharif Kazemi; Mahmood Zamirian; Kamran Aghasadeghi; Shahed Rezaian
Journal:  Int J Angiol       Date:  2007

Review 3.  Evaluation of drug-induced QT interval prolongation: implications for drug approval and labelling.

Authors:  M Malik; A J Camm
Journal:  Drug Saf       Date:  2001       Impact factor: 5.606

4.  Can abnormalities of ventricular repolarisation identify insulin dependent diabetic patients at risk of sudden cardiac death?

Authors:  P J Weston; J M Glancy; P G McNally; H Thurston; D P de Bono
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

5.  Use of lead adjustment formulas for QT dispersion after myocardial infarction.

Authors:  J M Glancy; C J Garratt; K L Woods; D P de Bono
Journal:  Br Heart J       Date:  1995-12

6.  Abnormal myocardial repolarisation in response to hypoxaemia and fenoterol.

Authors:  D G Kiely; R I Cargill; A Grove; A D Struthers; B J Lipworth
Journal:  Thorax       Date:  1995-10       Impact factor: 9.139

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.