Literature DB >> 22477271

Earliest time of change in QT dispersion after stenting in patients with single vessel coronary artery disease.

Gholam Reza Rezaian1, Hooman Shariati Ghadicolay, Mohammad Bagher Sharif Kazemi, Mahmood Zamirian, Kamran Aghasadeghi, Shahed Rezaian.   

Abstract

Dispersion of the QT interval (QTd) is a measure of inhomogeneity of ventricular repolarization, and its prolongation may provide a suitable substrate for life-threatening ventricular arrhythmias. The present study was performed to determine the onset time of change in the corrected QT (QTc) interval and QTd in patients with stable angina and single vessel coronary artery disease. Electrocardiograms of 60 patients with successful stenting, obtained 1 h before and 1 h, 6 h, 12 h and 24 h after the procedure were analyzed. The QTc interval, QTc maximum, QTc minimum and QTd were measured. All electrocardiograms were scanned, and then underwent computer-based analysis. There was a significant reduction in the mean QTc interval as early as 12 h after the procedure (from 474±41 ms to 460±31 ms; P<0.001), which persisted to the 24 h follow-up. This was associated with a significant reduction in mean QT maximum (from 496±31 ms to 418±66 ms; P<0.001) and a significant prolongation in mean QT minimum (from 403±21 ms to 444±12 ms; P<0.001) at the same time intervals. Therefore, successful stenting of coronary arteries in patients with single vessel coronary artery disease and stable angina decreases QTd as early as 12 h after the procedure. This phenomenon may be the result of improved regional myocardial circulation, and reduced ischemia. A persistently low QTd in the following months may therefore have prognostic significance, and can be used as a noninvasive marker of stent patency. Further studies are necessary to define the clinical applicability of QTd in the assessment of long-term stent patency in such patients.

Entities:  

Year:  2007        PMID: 22477271      PMCID: PMC2733007          DOI: 10.1055/s-0031-1278247

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  18 in total

1.  Effect of direct stent implantation on QTc dispersion.

Authors:  Yusuf Atmaca; Cagdas Ozdol; Fatih Ertas; Timucin Altin; Sadi Gülec; Dervis Oral
Journal:  Angiology       Date:  2005 Mar-Apr       Impact factor: 3.619

2.  Intracoronary electrocardiogram during coronary angioplasty.

Authors:  A K Pande; B Meier; P Urban; V Moles; P A Dorsaz; J Favre
Journal:  Am Heart J       Date:  1992-08       Impact factor: 4.749

3.  Spatial distribution of QT intervals: an alternative approach to QT dispersion.

Authors:  P Van Leeuwen; B Hailer; M Wehr
Journal:  Pacing Clin Electrophysiol       Date:  1996-11       Impact factor: 1.976

4.  Guidelines for percutaneous transluminal coronary angioplasty. A report of the American Heart Association/American College of Cardiology Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Committee on Percutaneous Transluminal Coronary Angioplasty).

Authors:  T J Ryan; W B Bauman; J W Kennedy; D J Kereiakes; S B King; B D McCallister; S C Smith; D J Ullyot
Journal:  Circulation       Date:  1993-12       Impact factor: 29.690

Review 5.  QT dispersion.

Authors:  P D Higham; R W Campbell
Journal:  Br Heart J       Date:  1994-06

6.  Changes in ventricular repolarization during percutaneous transluminal coronary angioplasty in humans assessed by QT interval, QT dispersion and T vector loop morphology.

Authors:  K Nowinski; S Jensen; G Lundahl; L Bergfeldt
Journal:  J Intern Med       Date:  2000-08       Impact factor: 8.989

7.  Automated measurement of QT interval dispersion from hard-copy ECGs.

Authors:  H K Bhullar; J C Fothergill; W P Goddard; D P de Bono
Journal:  J Electrocardiol       Date:  1993-10       Impact factor: 1.438

8.  Increased precordial QTc dispersion predicts ventricular fibrillation during acute myocardial infarction.

Authors:  A Yunus; A M Gillis; H J Duff; D G Wyse; L B Mitchell
Journal:  Am J Cardiol       Date:  1996-09-15       Impact factor: 2.778

9.  Effect of balloon inflation-induced acute ischemia on QT dispersion during percutaneous transluminal coronary angioplasty.

Authors:  K Aytemir; V Bavafa; N Ozer; S Aksoyek; A Oto; F Ozmen
Journal:  Clin Cardiol       Date:  1999-01       Impact factor: 2.882

10.  Increased QTc dispersion predicts lethal ventricular arrhythmias complicating coronary angioplasty.

Authors:  T Ashikaga; M Nishizaki; M Arita; N Yamawake; Y Kishi; F Numano; M Hiraoka
Journal:  Am J Cardiol       Date:  1998-09-15       Impact factor: 2.778

View more