Literature DB >> 8226414

Use of the E test for methicillin sensitivity testing.

G E Bignardi1, U Riley, C S Easmon.   

Abstract

Performance of the E test for methicillin sensitivity testing was investigated using 21 methicillin-resistant and 28 methicillin-sensitive staphylococci. Thirty of the strains had previously given equivocal results with a strip diffusion method. The E test performed well with Mueller-Hinton agar plates incubated at 30 degrees C for 24 h but only after supplementation with 5% NaCl. Testing on agar without salt was necessary for the recognition of methicillin resistance in one strain. We recommend a breakpoint of 4 mg/L and heavy inocula. The E test can be controlled by testing a control strain on the same plate.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8226414     DOI: 10.1093/jac/32.1.37

Source DB:  PubMed          Journal:  J Antimicrob Chemother        ISSN: 0305-7453            Impact factor:   5.790


  1 in total

1.  Comparison of disk diffusion, the E test, and detection of mecA for determination of methicillin resistance in coagulase-negative staphylococci.

Authors:  J G Mulder
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1996-07       Impact factor: 3.267