Literature DB >> 8214827

Coronary flow patterns in normal and ischemic hearts: transmyocardial and artery to vein distribution.

R Beyar1, R Caminker, D Manor, S Sideman.   

Abstract

The dynamics of the transmyocardial coronary flow patterns during normal and ischemic conditions are complex and relatively inaccessible to measurements. Therefore, theoretical analyses are needed to help in understanding these phenomena. The proposed model employs compartmental division to three layers, each with four vessel-size compartments which are characterized by resistance and compliance. These compartments are subjected to the extravascular compressive pressure (ECP) generated by cardiac contraction, which by modifying the transmural pressure causes changes in cross-sectional area of the vessels in each compartment continuously determining the resistance and capacitance values. Autoregulation and collaterals are also included in order to simulate the flow patterns during regional ischemia. Using these features, the model predicts the typical out of phase arterial and venous flow patterns. Systolic collapse of the large intramyocardial veins during the normal cycle, as well as systolic arteriolar collapse during ischemia are predicted. The transmural flow during ischemia is characterized by alternating flows between the layers. The ECP is considered here is two ways: (a) as a function of left ventricle (LV) pressure, decreasing linearly from endocardium to epicardium and (b) as the interstitial fluid pressure, employing a multilayer muscle-collagen model of the LV. While both of these approaches can describe the dynamics of coronary flow under normal conditions, only the second approach predicts the large compressive effects due to high ECP obtained at very low cavity pressure, resulting from significant muscle shortening and radial collagen stretch. This approach, combining a detailed description of transmural coronary circulation interacting with the contracting myocardium agrees with many observations on the dynamics of coronary flow and suggests that the type of LV mechanical model is important for that interaction.

Entities:  

Mesh:

Year:  1993        PMID: 8214827     DOI: 10.1007/bf02368635

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  30 in total

1.  Contractility is the main determinant of coronary systolic flow impediment.

Authors:  R Krams; P Sipkema; J Zegers; N Westerhof
Journal:  Am J Physiol       Date:  1989-12

2.  Mechanics of a thin walled collapsible microtube.

Authors:  P Sipkema; N Westerhof
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

3.  Microcirculation in the ventricle of the dog and turtle.

Authors:  H Tillmanns; S Ikeda; H Hansen; J S Sarma; J M Fauvel; R J Bing
Journal:  Circ Res       Date:  1974-04       Impact factor: 17.367

4.  Intramyocardial pressure. The persistence of its transmural gradient in the empty heart and its relationship to myocardial oxygen consumption.

Authors:  R J Baird; M M Goldbach; A De la Rocha
Journal:  J Thorac Cardiovasc Surg       Date:  1972-10       Impact factor: 5.209

5.  Fiber orientation in the canine left ventricle during diastole and systole.

Authors:  D D Streeter; H M Spotnitz; D P Patel; J Ross; E H Sonnenblick
Journal:  Circ Res       Date:  1969-03       Impact factor: 17.367

6.  Coronary pressure-flow relationships. Controversial issues and probable implications.

Authors:  F J Klocke; R E Mates; J M Canty; A K Ellis
Journal:  Circ Res       Date:  1985-03       Impact factor: 17.367

7.  Microcirculation of the epimyocardial layer of the heart. I. A method for in vivo observation of the microcirculation of superficial ventricular myocardium of the heart and capillary flow pattern under normal and hypoxic conditions.

Authors:  M Steinhausen; H Tillmanns; H Thederan
Journal:  Pflugers Arch       Date:  1978-12-15       Impact factor: 3.657

8.  Phasic coronary blood flow velocity in intramural and epicardial coronary arteries.

Authors:  W M Chilian; M L Marcus
Journal:  Circ Res       Date:  1982-06       Impact factor: 17.367

9.  The collagen network of the heart.

Authors:  J B Caulfield; T K Borg
Journal:  Lab Invest       Date:  1979-03       Impact factor: 5.662

10.  Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.

Authors:  J A Spaan; N P Breuls; J D Laird
Journal:  Circ Res       Date:  1981-09       Impact factor: 17.367

View more
  1 in total

1.  Effects of myocardial contraction on coronary blood flow: an integrated model.

Authors:  D Zinemanas; R Beyar; S Sideman
Journal:  Ann Biomed Eng       Date:  1994 Nov-Dec       Impact factor: 3.934

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.