Literature DB >> 8210735

Performance of an established system of first responder out-of-hospital defibrillation. The results of the second year of the Heartstart Scotland Project in the 'Utstein Style'.

M L Sedgwick1, K Dalziel, J Watson, D J Carrington, S M Cobbe.   

Abstract

The Heartstart Scotland project for out-of-hospital defibrillation covers the whole of Scotland, a population of approximately 5,102,400 (14.9% > 65 years, 48.3% male). All 395 ambulances in Scotland have been equipped with an automated external defibrillator and crews are trained in basic cardiopulmonary resuscitation and defibrillator use (EMT-D). Between 1 May 1990 and 30 April 1991 a total of 1700 cardiac arrests was reported by the ambulance service. Of the 1676 arrests which we could trace, 63% were witnessed. A total of 1383 (83%) of all patients were declared dead on arrival at hospital or in the emergency department, 119 (7%) died in hospital and 174 (10%) were discharged alive. Of the 174 survivors, 87% were conscious and normal at discharge, 9% had moderate residual disability and 2% severe disability. Survival of patients discharged alive from hospital was 85% at 1 year. Defibrillation was undertaken in 71% of the reported cardiac arrests. Survival of bystander witnessed arrests was increased from 7 to 15% with bystander CPR (P < 0.005). If the cardiac arrest was witnessed by the ambulance crew and required defibrillation, survival to discharge was 39%. Of bystander witnessed arrests reached while still in VF (n = 643), 11% were discharged alive. Patients who were defibrillated within 4 min of arrest had a 43% survival rate to hospital discharge.

Entities:  

Mesh:

Year:  1993        PMID: 8210735     DOI: 10.1016/0300-9572(93)90166-n

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  26 in total

1.  Automated external defibrillation: is survival only a shock away?

Authors:  B Schwartz; P R Verbeek
Journal:  CMAJ       Date:  2000-02-22       Impact factor: 8.262

2.  The role of automated external defibrillators in rural general practice.

Authors:  K Hanley; J Dowling; G Bury; A Murphy
Journal:  Br J Gen Pract       Date:  1999-04       Impact factor: 5.386

3.  Cost-effectiveness of automated external defibrillator deployment in selected public locations.

Authors:  Peter Cram; Sandeep Vijan; A Mark Fendrick
Journal:  J Gen Intern Med       Date:  2003-09       Impact factor: 5.128

4.  Surviving out of hospital cardiac arrest at home: a postcode lottery?

Authors:  R M Lyon; S M Cobbe; J M Bradley; N R Grubb
Journal:  Emerg Med J       Date:  2004-09       Impact factor: 2.740

5.  Regional variation in incidence and case fatality of myocardial infarction among young women in England, Scotland and Wales.

Authors:  N R Dunn; A Arscott; M Thorogood; B Faragher; L de Caestecker; T M MacDonald; C McCollum; S Thomas; R D Mann
Journal:  J Epidemiol Community Health       Date:  2000-04       Impact factor: 3.710

6.  Circadian variation in witnessed out of hospital cardiac arrest.

Authors:  L H Soo; D Gray; T Young; J R Hampton
Journal:  Heart       Date:  2000-10       Impact factor: 5.994

7.  The 1998 European Resuscitation Council guidelines for adult advanced life support. Advanced Life Support Working Group of the European Resuscitation Council.

Authors: 
Journal:  BMJ       Date:  1998-06-20

8.  Factors associated with survival to hospital discharge among patients hospitalised alive after out of hospital cardiac arrest: change in outcome over 20 years in the community of Göteborg, Sweden.

Authors:  J Herlitz; A Bång; J Gunnarsson; J Engdahl; B W Karlson; J Lindqvist; L Waagstein
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

9.  Pre-hospital cardiopulmonary resuscitation and pneumoperitoneum.

Authors:  T H Rainer; R Crawford
Journal:  J Accid Emerg Med       Date:  1995-12

10.  Sudden Cardiac Arrest in Athletic Medicine.

Authors:  Glenn C. Terry; James M. Kyle; James M. Ellis; John Cantwell; Ron Courson; Ron Medlin
Journal:  J Athl Train       Date:  2001-06       Impact factor: 2.860

View more