Scatter compensation in digital chest radiography using the posterior beam stop technique.

J Y Lo1, C E Floyd, J A Baker, C E Ravin.   

Abstract

A new scatter compensation technique for computed radiography based on posterior beam stop (PBS) sampled scatter measurements and the bicubic spline interpolation technique was proposed. Using only a single exposure, both the clinical image and an array of scatter measurements, which were interpolated into a smooth scatter-only image, were simultaneously acquired. The scatter was subtracted from the clinical image to generate the primary-only image. To gauge the accuracy of scatter estimation, both quantitative and interpolation errors were evaluated. The PBS measurements were compared against the standard beam stop method at 16 locations in an anatomical phantom, resulting in quantitative errors of 2.7% relative to the scatter or 6.8% relative to the primary. Also measured were the interpolation error over 64 interpolation sample locations and 64 midpoint sample locations in the anatomical phantom. The combined interpolation error was 1.9% relative to the scatter or 8.0% relative to the primary. At the interpolation sample locations, the errors were identical between the phantom radiograph and digital portable chest radiographs from five patients. By summing the quantitative and interpolation errors in quadrature, the overall error of the PBS SISTER (scatter interpolation-subtraction technique for radiography) method was 3.3% relative to the scatter or 10% relative to the primary, which was adequate for dual-energy imaging purposes (less than 10% error relative to the scatter or 20% relative to the primary). The change of image contrast, noise, and signal-to-noise ratio (SNR) at six locations in the anatomical phantom were quantitatively analyzed. Contrast and noise were equally enhanced in all anatomical regions, resulting in approximately the same SNR before and after compensation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8208219     DOI: 10.1118/1.597388

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Scatter correction method for x-ray CT using primary modulation: phantom studies.

Authors:  Hewei Gao; Rebecca Fahrig; N Robert Bennett; Mingshan Sun; Josh Star-Lack; Lei Zhu
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.