Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing blood.

M A Moehring1, J R Klepper.   

Abstract

A theory describing pulse Doppler ultrasound signals due to backscattering due to emboli in flowing blood is presented. From this theory, the minimum detectable size of a formed-element embolus can be established as a function of carrier frequency and vessel size. Emboli can be sized and characterized, based on the ratio of the amplitude of the Doppler signal during embolus passage through the sample volume to background bloodflow Doppler signal when no embolus is present. This ratio is defined as the "embolus to blood ratio" (EBR). Size estimation of emboli can be done by insonating an embolus with a single frequency and measuring the EBR, only if the embolus does not exceed a certain size, and if the vessel diameter and per cent hematocrit are known. Using two different frequencies, the vessel geometry (diameter and sample volume length) and per cent hematocrit can be eliminated from calculation of embolus size. Sources of uncertainty in the EBR and their effect on embolus size estimation are discussed. Discrimination between gas and formed-element emboli is described, given a detector with sufficient dynamic range, and use of three carrier frequencies. The theory presented here is in agreement with experimental findings of other investigators.

Entities:  

Mesh:

Year:  1994        PMID: 8200666     DOI: 10.1109/10.277269

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  A pilot randomized clinical safety study of sonothrombolysis augmentation with ultrasound-activated perflutren-lipid microspheres for acute ischemic stroke.

Authors:  Andrei V Alexandrov; Robert Mikulik; Marc Ribo; Vijay K Sharma; Annabelle Y Lao; Georgios Tsivgoulis; Rebecca M Sugg; Andrew Barreto; Paul Sierzenski; Marc D Malkoff; James C Grotta
Journal:  Stroke       Date:  2008-03-20       Impact factor: 7.914

2.  Sonothrombolysis in ischemic stroke.

Authors:  Kristian Barlinn; Andrei V Alexandrov
Journal:  Curr Treat Options Neurol       Date:  2013-04       Impact factor: 3.598

3.  Sizing gaseous emboli using Doppler embolic signal intensity.

Authors:  Caroline Banahan; James P Hague; David H Evans; Rizwan Patel; Kumar V Ramnarine; Emma M L Chung
Journal:  Ultrasound Med Biol       Date:  2012-03-06       Impact factor: 2.998

4.  Size distribution of air bubbles entering the brain during cardiac surgery.

Authors:  Emma M L Chung; Caroline Banahan; Nikil Patel; Justyna Janus; David Marshall; Mark A Horsfield; Clément Rousseau; Jonathan Keelan; David H Evans; James P Hague
Journal:  PLoS One       Date:  2015-04-02       Impact factor: 3.240

Review 5.  Tissue plasminogen activator-based clot busting: Controlled delivery approaches.

Authors:  Ibrahim M El-Sherbiny; Islam E Elkholi; Magdi H Yacoub
Journal:  Glob Cardiol Sci Pract       Date:  2014-10-16

6.  Thrombus size and Doppler embolic signal intensity.

Authors:  Matthew J Martin; Emma M L Chung; Kumar V Ramnarine; Alison H Goodall; A Ross Naylor; David H Evans
Journal:  Cerebrovasc Dis       Date:  2009-08-22       Impact factor: 2.762

7.  An in vitro comparison of embolus differentiation techniques for clinically significant macroemboli: dual-frequency technique versus frequency modulation method.

Authors:  Caroline Banahan; Zach Rogerson; Clément Rousseau; Kumar V Ramnarine; David H Evans; Emma M L Chung
Journal:  Ultrasound Med Biol       Date:  2014-09-11       Impact factor: 2.998

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.