Literature DB >> 8199106

Possibilities and limitations of radioimmunoscintigraphy and conventional diagnostic modalities in choroidal melanoma.

D F Schaling1, J A Oosterhuis, M J Jager, H Kakebeeke-Kemme, E K Pauwels.   

Abstract

A prospective clinical study to assess the value of immunoscintigraphy with a monoclonal antibody (MoAb) against high molecular weight melanoma associated antigen (225.28S) was performed in 43 patients with choroidal melanoma; in six patients with a lesion suspected of being choroidal melanoma, and in seven patients with a benign lesion simulating a choroidal melanoma. The results of immunoscintigraphy in choroidal melanoma were compared with results of conventional diagnostic modalities like ultrasonography and fluorescein angiography. Planar scintigraphy showed a detection rate of 49% which is comparable with other studies. The detection with scintigraphy was correlated to the size of the choroidal melanoma. The use of single photon computed tomography did not increase the sensitivity of immunoscintigraphy. Ultrasonography yielded a correct diagnosis in 37 of 42 melanomas (88%). With fluorescein angiography a correct diagnosis was obtained in 11 of 30 melanomas (36.6%). The value of immunoscintigraphy with MoAb 225.28S in small choroidal melanomas is limited; its reliability increases in large tumours. Immunohistochemistry with MoAb 225.28S showed antigen expression in 95% of the stained tissue specimens of choroidal melanoma.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8199106      PMCID: PMC504755          DOI: 10.1136/bjo.78.4.244

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  13 in total

1.  Continuous cultures of fused cells secreting antibody of predefined specificity.

Authors:  G Köhler; C Milstein
Journal:  Nature       Date:  1975-08-07       Impact factor: 49.962

2.  Heterogeneous expression of melanoma-associated antigens in uveal melanomas.

Authors:  J P van der Pol; M J Jager; D de Wolff-Rouendaal; P J Ringens; C Vennegoor; D J Ruiter
Journal:  Curr Eye Res       Date:  1987-06       Impact factor: 2.424

Review 3.  Fluorescein angiography. An aid in the differential diagnosis of intraocular tumors.

Authors:  J D Gass
Journal:  Int Ophthalmol Clin       Date:  1972

4.  Radioimmunoscintigraphy and immunohistochemistry with melanoma-associated monoclonal antibodies in choroidal melanoma: a comparison of the clinical and immunohistochemical results.

Authors:  D F Schaling; J P van der Pol; M J Jager; M J van Kroonenburgh; J A Oosterhuis; D J Ruiter
Journal:  Br J Ophthalmol       Date:  1990-09       Impact factor: 4.638

5.  Immunoscintigraphy in intraocular malignant melanoma.

Authors:  K Scheidhauer; A Markl; G Leinsinger; E Moser; O F Scheiffarth; K G Riedel; T S Schaal; F H Stefani; U Schumacher
Journal:  Nucl Med Commun       Date:  1988-09       Impact factor: 1.690

6.  Three-step monoclonal antibody tumor targeting in carcinoembryonic antigen-positive patients.

Authors:  G Paganelli; P Magnani; F Zito; E Villa; F Sudati; L Lopalco; C Rossetti; M Malcovati; F Chiolerio; E Seccamani
Journal:  Cancer Res       Date:  1991-11-01       Impact factor: 12.701

7.  Immunoimaging of choroidal melanoma: assessment of its diagnostic accuracy and limitations in 101 cases.

Authors:  J Scheidler; G Leinsinger; C M Kirsch; O F Scheiffarth; F H Stefani; K G Riedel
Journal:  Br J Ophthalmol       Date:  1992-08       Impact factor: 4.638

8.  Ocular melanoma: detection using iodine-123-iodoamphetamine and SPECT imaging.

Authors:  S H Dewey; J C Leonard
Journal:  J Nucl Med       Date:  1990-03       Impact factor: 10.057

9.  Immunoscintigraphy in malignant melanoma: a five-year clinical experience.

Authors:  L Feggi; M Indelli; G C Pansini; A Santini; N Prandini; A R Virgili
Journal:  Nucl Med Commun       Date:  1993-02       Impact factor: 1.690

10.  Reduction of background activities by introduction of a diester linkage between antibody and a chelate in radioimmunodetection of tumor.

Authors:  C H Paik; K Yokoyama; J C Reynolds; S M Quadri; C Y Min; S Y Shin; P J Maloney; S M Larson; R C Reba
Journal:  J Nucl Med       Date:  1989-10       Impact factor: 10.057

View more
  1 in total

1.  Immunoscintigraphy for ocular melanoma: a reliable diagnostic technique?

Authors:  K U Loeffler; P Bräutigam; J C Simon; S R Althauser; C Wuttig; H Witschel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-02       Impact factor: 3.117

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.