Literature DB >> 8198900

Modification of the iso-shunt lines for low inspired oxygen concentrations.

A J Petros1, C J Doré, J F Nunn.   

Abstract

Arterial PO2 (PaO2) has been related to inspired oxygen concentration (FIO2 range 0.21-0.60) in 20 patients, breathing spontaneously, while recovering from a range of conditions treated in an intensive therapy unit. There was a highly significant linear trend (P < 0.001) for the mean venous admixture ("virtual shunt"), calculated from the iso-shunt diagram (model A), to increase from 0.11 to 0.19 as FIO2 decreased from 0.60 to 0.21. As this appeared to be caused by relative ventilation/perfusion (V/Q) mismatch, we prepared a second model (model B) with a variable two-compartment relative V/Q mismatch in addition to a shunt. Regression of the degree of mismatch on the shunt gave good agreement between predicted and observed PaO2 values (mean bias -0.17 kPa, pooled within patient SD 1.22). Model B is now proposed to extend the applicability of the iso-shunt diagram for FIO2 values less than 0.35. Published postoperative PaO2 data from other workers showed good agreement with our final model (mean bias 0.10 kPa, pooled SD 0.41). The new diagram may therefore have wide applicability in the field of anaesthesia and intensive care.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8198900     DOI: 10.1093/bja/72.5.515

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Reproduction of inert gas and oxygenation data: a comparison of the MIGET and a simple model of pulmonary gas exchange.

Authors:  Stephen E Rees; S Kjaergaard; S Andreassen; G Hedenstierna
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

2.  Respiratory mechanics in brain-damaged patients.

Authors:  Antonia Koutsoukou; Helen Perraki; Asimina Raftopoulou; Nikolaos Koulouris; Christina Sotiropoulou; Anastasia Kotanidou; Stylianos Orfanos; Charis Roussos
Journal:  Intensive Care Med       Date:  2006-10-20       Impact factor: 17.440

3.  The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10-15 minutes.

Authors:  Stephen Edward Rees; Søren Kjaergaard; Per Perthorgaard; Jerzy Malczynski; Egon Toft; Steen Andreassen
Journal:  J Clin Monit Comput       Date:  2002-01       Impact factor: 2.502

4.  Non-invasive estimation of shunt and ventilation-perfusion mismatch.

Authors:  Søren Kjaergaard; Stephen Rees; Jerzy Malczynski; Jørgen Ahrenkiel Nielsen; Per Thorgaard; Egon Toft; Steen Andreassen
Journal:  Intensive Care Med       Date:  2003-04-16       Impact factor: 17.440

Review 5.  Estimating intracardiac and extracardiac shunting in the setting of complex congenital heart disease.

Authors:  Ryan J Stark; Lara S Shekerdemian
Journal:  Ann Pediatr Cardiol       Date:  2013-07

6.  On the practical identifiability of a two-parameter model of pulmonary gas exchange.

Authors:  Axel Riedlinger; Jörn Kretschmer; Knut Möller
Journal:  Biomed Eng Online       Date:  2015-09-04       Impact factor: 2.819

  6 in total