Literature DB >> 8188729

An investigation on the accuracy of three-dimensional space reconstruction using the direct linear transformation technique.

L Chen1, C W Armstrong, D D Raftopoulos.   

Abstract

An investigation on the three-dimensional calibration errors associated with the direct linear transformation (DLT) technique was carried out using a two video camera system. Thirty different configurations in five groupings of different numbers of control points were tested. The results showed that the accuracy improved as the number of control points increased from 8 to 24. Further, it was demonstrated that the best accuracy was achieved when the control points were evenly distributed throughout the control region. For the system under investigation, an accuracy of 1-2 mm in the x and y directions, 4-6 mm in the z direction and 6-7 mm for the resultant was obtained in a control space of 2.10 x 1.35 x 1.00 m. Additionally, the accuracy for points outside the control space and the systematic error associated with the control object were studied. Tests were done on a 32-point rectangular calibration frame, and the results indicated that the calibration errors could be reduced by 20-40% when an appropriate quadratic function was used to modify the standard DLT method.

Mesh:

Year:  1994        PMID: 8188729     DOI: 10.1016/0021-9290(94)90024-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  17 in total

1.  Quantifying cross-scatter contamination in biplane fluoroscopy motion analysis systems.

Authors:  Janelle A Cross; Ben McHenry; Taly Gilat Schmidt
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-23

2.  Quantitative Evaluation of the In Vivo Vocal Fold Medial Surface Shape.

Authors:  Andrew M Vahabzadeh-Hagh; Zhaoyan Zhang; Dinesh K Chhetri
Journal:  J Voice       Date:  2017-01-12       Impact factor: 2.009

3.  Digital stereophotogrammetry based on circular markers and zooming cameras: evaluation of a method for 3D analysis of small motions in orthopaedic research.

Authors:  Evgenij Bobrowitsch; Christof Hurschler; Gavin Olender; Christian Plaass; Hazibullah Waizy; Heino Arnold; Christina Stukenborg-Colsman
Journal:  Biomed Eng Online       Date:  2011-02-01       Impact factor: 2.819

4.  Vibratory responses of synthetic, self-oscillating vocal fold models.

Authors:  Preston R Murray; Scott L Thomson
Journal:  J Acoust Soc Am       Date:  2012-11       Impact factor: 1.840

5.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques.

Authors:  Daniel L Miranda; Joel B Schwartz; Andrew C Loomis; Elizabeth L Brainerd; Braden C Fleming; Joseph J Crisco
Journal:  J Biomech Eng       Date:  2011-12       Impact factor: 2.097

6.  Three-dimensional posture changes of the vocal fold from paired intrinsic laryngeal muscles.

Authors:  Andrew M Vahabzadeh-Hagh; Zhaoyan Zhang; Dinesh K Chhetri
Journal:  Laryngoscope       Date:  2016-07-05       Impact factor: 3.325

7.  EFFECTS OF A LIGHTER DISCUS ON SHOULDER MUSCLE ACTIVITY IN ELITE THROWERS, IMPLICATIONS FOR INJURY PREVENTION.

Authors:  Daniel Dinu; Nicolas Houel; Julien Louis
Journal:  Int J Sports Phys Ther       Date:  2019-07

8.  Real-time human motion estimation using biomechanical models and non-linear state-space filters.

Authors:  P Cerveri; M Rabuffetti; A Pedotti; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

9.  Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique.

Authors:  A Mitulescu; I Semaan; J A De Guise; P Leborgne; C Adamsbaum; W Skalli
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

10.  Reconstruction Error of Calibration Volume's Coordinates for 3D Swimming Kinematics.

Authors:  Pedro Figueiredo; Leandro Machado; João Paulo Vilas-Boas; Ricardo J Fernandes
Journal:  J Hum Kinet       Date:  2011-10-04       Impact factor: 2.193

View more